Search results for "Thermometer"
Dukal Thermometer Jar 4", Stainless Steel
Made of the high grade stainless steel (18/8,304) Crafted without seams which prevents bacteria growth and allows for easy cleaning Autoclavable Attributes Brand Name Tech-Med Size 1" x 4" Material 18/8 Stainless Steel Sterile No Weight 2.31485 lbs Packaging Packaging 12/BX Case Packaging 12/BX Total Case Quantity 12 Item Packaging Barcode 665973021799 Inner Packaging Barcode (01)10665973021796 Case Packaging Barcode (01)20665973021793
SKU: 4236-D
$149.99 $138.99
Dukal Digital Thermometer
Quick 10 Second read with LCD display and low battery indicator Reads both Centigrade and Fahrenheit Alarm/Beeper when reading is complete Battery life: 200 hours of continuous operation Auto shut off after 9 minutes of non use Built in memory enabling display of the previously measured value Water resistant Range: 32° - 43.9°c, 90º - 109.9º f Attributes Brand Name Tech-Med Sterile No Weight 24.14062 lbs Packaging Packaging 12/BX, 30 BX/CS Inner Packaging 12/BX Case Packaging 30 BX/CS Total Case Quantity 36 Item Packaging Barcode (01)10665973017089 Inner Packaging Barcode (01)20665973017086 Case Packaging Barcode (01)30665973017083
SKU: 3210D-360
$28.07 $25.06
B. Braun Medical Intergrated Wall System Connex Welch Allyn Connex Integrated Wall System with Masimo SpO2, SureTemp Plus Thermometry, Braun ThermoScan PRO 6000 Thermometry
For use on adult, pediatric and neonatal patients Integrated 3.5v handles for physical assessment instruments (otoscope and ophthalmoscope) Spot check and timed intervals monitoring Fast, comfortable blood pressure with SureBP technology Option of Masimo® or Nellcor® SpO Connect to digital weight scales from SECA Health-o-Meter® and Detecto Up to 20 custom modifiers for more complete patient documentation Single sign-on options available for quick, secure clinician login Manufacturer # 84MTVE2-US Brand Connex® Manufacturer Welch Allyn Country of Origin United States Application Intergrated Wall System Blood Pressure Measurement SureBP NIPB Dispenser Type Ear Specula Dispenser Instrument Type Welch Allyn Connex Integrated Wall System with Masimo SpO2, SureTemp Plus Thermometry, Braun ThermoScan PRO 6000 Thermometry, BP Cuff and Cord Management System, Integrated MacroView Basic LED Otoscope and PanOptic Basic LED Ophthalmoscope, Mounting Type Wall Mount Ophthalmoscope PanOptic Ophthalmoscope Otoscope MacroView Otoscope Thermometer Braun ThermoScan PRO 6000 UNSPSC Code 42181904
SKU: 84MTVE2-US
$8,852.21 $6,786.69
B. Braun Medical Intergrated Wall System Welch Allyn Welch Allyn Connex Integrated Wall System with Masimo SpO2, SureTemp Plus Thermometry, Braun ThermoScan PRO 6000 Thermometry
Large color touchscreen display simplifies training and operation Eliminates frustrating and time-consuming searches for individual pieces of equipment throughout the facility Prevents tools from being lost, stolen or misplaced Enhances the visibility of information to your patients and improves communication and compliance Saves valuable floor space and minimizes device wear and tear Allows clinicians to immediately view all necessary patient data, then send it directly to an EHR system Provides accurate data every time, speeding decision-making and improving patient safety Descriptive error messages for easy troubleshooting • Integrated 3.5 V handles for physical assessment instruments Manufacturer # 84MTVX2-US Brand Welch Allyn Manufacturer Welch Allyn Country of Origin United States Application Intergrated Wall System Blood Pressure Measurement SureBP NIBP Dispenser Type Integrated Ear Speculum Dispenser Instrument Type Welch Allyn Connex Integrated Wall System with Masimo SpO2, SureTemp Plus Thermometry, Braun ThermoScan PRO 6000 Thermometry, BP Cuff and Cord Management System, Integrated MacroView Basic LED Otoscope and PanOptic Basic LED Ophthalmoscope, SureBP Non-invasive Blood Pressure, Pulse Rate, MAP, Programmable Alarms Mounting Type Wall Mount Ophthalmoscope Coaxial Ophthalmoscope Otoscope MacroView Otoscope Thermometer SureTemp Plus Thermometry UNSPSC Code 42181904
SKU: 84MTVX2-US
$8,211.69 $6,295.63
B. Braun Medical Integrated Wall Diagnostic System Connex Welch Allyn Connex Integrated Wall System with Nellcor SpO2, SureTemp Plus Thermometry, Braun ThermoScan PRO 6000 Thermometry
Simple color touchscreen interface For use on adult, pediatric and neonatal patients Integrated 3.5v handles for physical assessment instruments (otoscope and ophthalmoscope) Spot check and timed intervals monitoring • Fast, comfortable blood pressure with SureBP technology Blood pressure averaging to help ensure accurate hypertension diagnosis Option of Masimo® or Nellcor® SpO2 Connect to digital weight scales from SECA Health-o-Meter® and Detecto Up to 20 custom modifiers for more complete patient documentation Manufacturer # 84NTVE2-US Brand Connex® Manufacturer Welch Allyn Country of Origin United States Application Integrated Wall Diagnostic System Blood Pressure Measurement SureBP NIP Instrument Type Welch Allyn Connex Integrated Wall System with Nellcor SpO2, SureTemp Plus Thermometry, Braun ThermoScan PRO 6000 Thermometry, BP Cuff and Cord Management System, Integrated MacroView Basic LED Otoscope and PanOptic Basic LED Ophthalmoscope, SureBP Non-invasive Blood Pressure, Pulse Rate Mounting Type Wall Mount Ophthalmoscope PanOptic Ophthalmoscope Otoscope MacroView Otoscope Thermometer SureTemp Plus Thermometry, Braun ThermoScan PRO 6000 UNSPSC Code 42181904
SKU: 84NTVE2-US
$11,413.85 $8,750.61
Terragene AutoReader Incubator for BT98, 2 Positions. 1/bx
BHY HYPER / Auto-reader Incubator for incubation and readout of Hyper Rapid Self-Contained Biological Indicators. For incubation and readout of Hyper Rapid Self-Contained Biological Indicators BT98 (VH2O2) readout fluorescense system after 5 minutes of incubation at 60 ºC. Characteristics: 2 readout positions (38 mm deep, 9 mm diameter) for incubation of Hyper Rapid Biological Indicators. 1 ampoule crusher. Special hole for external thermometer. Unique ID Number for each carried out results for audit purposes. Easy access to the last 50 results. USB connection for registering results in a PC through Reading and Traceability Software. Bluetooth wireless technology connectivity. Fully compatible with Bionova Cloud Traceability Software. Fully compatible with Terragene Wireless Assistant App for Mobile Devices. Sound alarm for event indication. Detection and automatic cancellation of the fluorescence reading of the biological indicator. Specifications: Fluorescence reading wavelength: ~ 460 nm Firmware update by the user. Dimensions: 10 mm high, 97 mm wide and 103 mm deep. Power: 18 W Frequency: 50-60 Hz Read-Out Time: 5 min Operating specifications: Input 100/240V 0.2A (50/60Hz)|Output: 12V 4A Working temperature: 60 ± 2°C More Info About This Product: User Manual
SKU: HYPER
$1,800.99 $1,499.99
Terragene Autoreaders 12 Positions Premium, 1/bx, 4rl/bx
IC10/20FRLCD / Auto-Reader Incubator For incubation and readout of Rapid, Super Rapid or Ultra Rapid Biological Indicators and Hygiene Monitoring Systems with 3.5″ touchscreen display. For Incubation And Readout Of: Bionova® Rapid Fluorescence Readout Biological Indicators: BT220 (Steam): 3 hs. at 60 ºC, BT221 (Steam): 1 h. at 60 ºC and BT110 (EO): 4 hs. at 37 ºC, BT102 (Formaldehyde): 2 hs. at 60 ºC. BT95 (VH2O2): 2 hs. at 60ºC. Bionova® Super Rapid Fluorescence Readout Biological Indicators: BT222 (Steam): 1 h. at 60 ºC, BT223 (Steam): 30 min. at 60 ºC, BT96 (VH2O2): 30 min. at 60ºC. Bionova® Ultra Rapid Fluorescence Readout Biological Indicators: BT224 (Steam): 20 min. at 60ºC. Chemdye® PRO1 MICRO Pen Protein System: 15 min at 60 ºC . Characteristics: 12 metal positions (3.8 cm deep, 0.9 cm diameter) to incubate Rapid/Super Rapid/Ultra Rapid Fluorescence Readout Self-contained biological indicators. 1 metal position (3.8 cm deep, 1.0 cm diameter) to incubate Protein Pen. Special hole for external thermometer. 1 ampoule crusher. 3.5 ” touchscreen LCD. Visual information of the remaining time of the incubation process. Temperature display on the screen and remaining time for each position. Dual Temperature System: Allows selecting between two different incubation temperatures (37ºC y 60ºC). Allows running different incubation times simultaneously, provided they are of equal incubation temperature. Audible alarm for event indications. ETHERNET connection for recording results on PC using a Reading and Traceability software. Remote display of the screen in PC and Smartphones. It stores the last 208 results. Thermal Printer of Results. Allows reprinting the last 208 results. Automatic detection and cancelation of biological indicator fluorescence reading. Specifications: Fluorescence reading wave length: ~ 460 nm Dimensions: 18.0 cm high, 26.0 cm diameter. Weight: 1.92 Kg. Voltage range: 100 €“ 240 V AC Power: 28 W Frequency: 50-60 Hz Operating Specifications: Input 100/240V 0.2A (50/60Hz)|Output: 12V 4A Working Temperature: 37 ± 2°C, 60 ± 2°C More Info About This Product: User Manual
SKU: IC102FRLCD
$1,410.99 $1,399.99
Terragene MiniBio, Autoreader, 3 Positions
MINIBIO / Auto-reader Incubator for Biological Indicators with 3 positions and built-in printer. For incubation and readout of: Bionova® Rapid Fluorescence Readout Biological Indicators: BT220 (Steam): 3 hs. at 60 ºC, BT221 (Steam): 1 h. at 60 ºC, BT110 (EO): 4 hs. at 37 ºC, BT102 (Formaldehyde): 2 hs. at 60ºC, BT95 (VH2O2): 2 hs. at 60ºC. Bionova® Super Rapid Fluorescence Readout Biological Indicators: BT222 (Steam): 1 h. at 60 ºC, BT223 (Steam): 30 min. at 60 ºC, BT96 (VH2O2): 30 min. at 60ºC. Bionova® Ultra Rapid Fluorescence Readout Biological Indicators: BT224 (Steam): 20 min. at 60ºC. Characteristics: 3 metal positions (38 mm deep, 9 mm diameter) to incubate Rapid/Super Rapid/Ultra Rapid Fluorescence Readout Self-contained biological indicators. 1 ampoule crusher. Special hole for external thermometer. Incorporated top cap. Dual Temperature System: Allows selecting between two different incubation temperatures (37ºC and 60ºC) USB connection for registering results in a PC through Reading and Traceability Software. Allows incubating 3 indicators simultaneously, in different incubation times, at the same temperature. Thermal Printer to record results. Sound alarm for event indication Detection and automatic cancellation of the fluorescence reading of the biological indicator. Specifications: Fluorescence Reading Wavelength: ~ 460 nm Firmware Update By The User. Dimensions: 180 mm High, 154 mm wide and 105 mm deep. Voltage Range: 100 €“ 240 V AC Power: 28 W Frequency: 50-60 Hz Operating Specifications: Input 100/240V 0.2A (50/60Hz)|Output: 12V 4A Working Temperature: 37 ± 2°C, 60 ± 2°C More Info About This Product: User Manual
SKU: MINIBIO
$799.99 $610.99
Terragene Autoreaders 12 Positions, 1/bx
IC10/20FR / Auto-Reader Incubator For incubation and readout of Rapid, Super Rapid or Ultra Rapid Biological Indicators and Hygiene Monitoring Systems. For Incubation And Readout Of: Bionova® Rapid Fluorescence Readout Biological Indicators: BT220 (Steam): 3 hs. at 60 ºC, BT221 (Steam): 1 h. at 60 ºC and BT110 (EO): 4 hs. at 37 ºC, BT102 (Formaldehyde): 2 hs. at 60 ºC. BT95 (VH2O2): 2 hs. at 60ºC. Bionova® Super Rapid Fluorescence Readout Biological Indicators: BT222 (Steam): 1 h. at 60 ºC, BT223 (Steam): 30 min. at 60 ºC, BT96 (VH2O2): 30 min. at 60ºC. Bionova® Ultra Rapid Fluorescence Readout Biological Indicators: BT224 (Steam): 20 min. at 60ºC. Chemdye® PRO1 MICRO Pen Protein System: 15 min at 60 ºC . Characteristics: 12 metal positions (3.8 cm deep, 0.9 cm diameter) to incubate Rapid/Super Rapid/Ultra Rapid Fluorescence Readout Self-contained biological indicators. 1 metal position (3.8 cm deep, 1.0 cm diameter) to incubate Protein Pen. Special hole for external thermometer. 1 ampoule crusher. Dual Temperature System: Allows selecting between two different incubation temperatures. Allows running different incubation times simultaneously. USB connection for registering results in a PC through Reading and Traceability Software. Thermal Printer to record results in sterilization book. Automatic detection and cancelation of biological indicator fluorescence reading. Specifications: Fluorescence Reading Wave Length: ~ 460 nm Dimensions: 18.0 cm high, 26.0 cm diameter. Weight: 1.92 Kg. Voltage Range: 100 €“ 240 V AC Power: 28 W Frequency: 50-60 Hz Operating Specifications: Input 100/240V 0.2A (50/60Hz)|Output: 12V 4A Working Temperature: 37 ± 2°C, 60 ± 2°C More Info About This Product: User Manual
SKU: IC102FR
$1,410.99 $1,070.99
Terragene Fluorescence SCBI For EO, 37°C (4 hour), 50/Bx
Rapid Self-contained Biological Indicator for Ethylene Oxide sterilization processes. Bacillus atrophaeus (ATCC 9372) 10^6 spores per vial. Readout: 4 hours. An optional visual pH color change confirmation could be made after 48 hours of incubation. If sterilization process has not been successful, culture medium will change to a greenish color first, and then to yellow during incubation at 37 ºC, thus showing the presence of living spores. If sterilization process is successful culture medium will remain blue after the incubation process. 7-day readout for visual confirmation by color change is optional and not intended to be routinely performed; it is an initial validation of the 4 hour-reading. Fluorescence results may be compared to the 7-day visual reading. Instructions For Use: Identify the Terragene® Bionova® BT110 SCBI by writing the sterilizer number (in case of having more than one), load number and processing date on the label. Pack the SCBI along with materials to be sterilized in an appropriate package according to recommended sterilization practices. Place the package in those areas which are considered most inaccessible for the sterilizing agent (e.g., the center of the load and areas near the door). Sterilize as usual. After the sterilization process has finished, open the sterilizer door, wait five minutes and remove the SCBI from the package. CAUTION: Wear safety glasses and gloves when removing the Terragene® Bionova® BT110 SCBI from the sterilized package. Check the Process Indicator on SCBI label. A color change to green indicates that the SCBI has been exposed to Ethylene Oxide. IMPORTANT: This color change does not evidence the process effectiveness to achieve sterility. If the color of the Process Indicator has not changed, check the sterilization process. Press the lid to seal the tube. Crush the ampoule contained in the SCBI with an individual ampoule crusher or with the ampoule crusher placed within the incubator´s incubation area. Then shake the tube down vigorously, with movements similar to those performed to lower the temperature in a mercury thermometer, until the medium reaches the base of the tube and soaks the spore carrier entirely. Finally, place the SCBI in the incubator. Incubate the processed indicator and the positive control indicator in the appropriate Terragene® Bionova® Auto-Reader incubators for a maximum of 4 hours at (37 ± 2) °C for rapid readout. Note: Holding time between sterilization and incubation should not exceed a 7-day period. Fluorescence detection by the reader (excitation 340-380 nm / emission 455-465 nm) means failure in the sterilization process. If no fluorescence is detected after 4 hours of incubation, the result is negative. The positive control must give positive fluorescence readout. It is good practice to incubate a positive control for visual color change. If chamber relative humidity is unknown or < 35 %, continue to incubate the Biological Indicator for a pH color change result, since low relative humidity may increase the fluorescent readout time beyond 4 hours. Specifications: Process: Ethylene Oxide Microorganism: Bacillus atrophaeus (ATCC 9372) Population: 10^6 Spores/carrier Read-Out Time: 4 h Regulations: IRAM 37102-1, IRAM 37102-2, ISO 11138-1, ISO 11138-2 Length: 40 mm
SKU: BT110
$250.99 $210.99
Terragene Fluorescence Ultra Rapid SCBI For H2O2. 60°C (30 minutes), 50/Bx
Super Rapid Self-contained Biological Indicator for Plasma or Vaporized Hydrogen Peroxide Sterilization Processes. Final readout: 30 minutes. An optional visual pH color change confirmation could be performed after 48 hours of incubation. If sterilization process has not been successful, culture medium will change to yellow during incubation at 60 ºC, thus showing the presence of living spores. If sterilization process is successful culture medium will remain purple after the incubation process. 7-day readout is optional and not intended to be routinely performed; it is an initial validation of the 30-minute reading. Fluorescence results may be compared to the 7-day visual reading. Note: If 7-day readout is performed, a humidified environment will be required to prevent medium from drying out. Instructions For Use: Identify the Terragene® Bionova® BT96 SCBI by writing the sterilizer number (in case of having more than one), load number and processing date on the label. Pack the SCBI along with materials to be sterilized in an appropriate package according to recommended sterilization practices. Place the package in those areas which are considered most inaccessible for the sterilizing agent (e.g., the center of the load and areas near the door). Sterilize as usual. After the sterilization process has finished, open the sterilizer door, wait five minutes and remove the SCBI from the package. CAUTION: Wear safety glasses and gloves when removing the Terragene® Bionova® BT96 SCBI from the sterilized package.( Do not crush or handle the SCBI excessively, since this might cause the glass ampoule to burst. Let the SCBI cool down until it reaches room temperature.) Check the Process Indicator on SCBI label. A color change to green indicates that the SCBI has been exposed to Hydrogen Peroxide. IMPORTANT: This color change does not evidence the process effectiveness to achieve sterility. If the color of the Process Indicator has not changed, check the sterilization process. 6. Press the lid to seal the tube. Crush the ampoule contained in the SCBI with an individual ampoule crusher or with the ampoule crusher placed within the incubator´s incubation area. Then shake the tube down vigorously, with movements similar to those performed to lower the temperature in a mercury thermometer, until the medium reaches the base of the tube and soaks the spore carrier entirely. Finally, place the SCBI in the incubator. Incubate the processed indicator and the positive control indicator in the appropriate Terragene® Bionova® Auto-Reader incubators for a maximum of 30 minutes at (60 ± 2) °C for super rapid readout. Important: Use a non-sterilized SCBI as a positive control at least once per day, when a sterilization cycle is run. The positive control ensures that correct incubation conditions were met; the capability of the medium to promote rapid growth; viability of spores has not been altered due to improper storage temperature, humidity or proximity to chemicals and proper functioning of Terragene® Bionova® Auto-Reader Incubators. Both, the positive control indicator and the processed indicator, should belong to the same batch. Note: Holding time between sterilization and incubation should not exceed a 7-day period. Fluorescence detection by the reader (excitation 340-380 nm / emission 455-465 nm) means failure in the sterilization process. If no fluorescence is detected after 30 minutes of incubation, the result is negative. The positive control must give positive fluorescence readout. It is good practice to incubate a positive control for visual color change. Specifications: Process: Hydrogen peroxide Microorganism: Geobacillus stearothermophilus (ATCC 7953) Population: 10^6 Spores/carrier Read-Out Time: 30 min Regulations: IRAM 37102-1, ISO 11138-1
SKU: BT96
$390.99 $315.99
Terragene Fluorescence SCBI For Steam. 60°C (20 minutes), Ultra Rapid, 50/bx
Ultra Rapid Self-contained Biological Indicator for Steam sterilization processes. Geobacillus stearothermophilus (ATCC 7953) 10^6 spores per vial. Readout: 20 minutes. An optional visual pH color change confirmation could be made after 48 hours of incubation. If the sterilization process has not been successful, the culture medium will change to a greenish color first, and then to yellow during incubation at 60 ºC, thus showing the presence of living spores. If the sterilization process is successful culture medium will remain purple after the incubation process. 7-day readout is optional and not intended to be routinely performed; it is an initial validation of the 20 minute-reading. Fluorescence results may be compared to the 7-day visual reading. Note: If 7-day readout is performed, a humidified environment will be required to avoid medium to dry out. D-Value: Not lower than 1.5 minutes at 121 ºC. Another D-value is informed at 132ºC and at 135ºC. Z-Value is informed. Instructions For Use: Identify the Terragene® Bionova® BT224 SCBI by writing the sterilizer number (in case of having more than one), load number and processing date on the label. Pack the SCBI along with materials to be sterilized in an appropriate package according to recommended sterilization practices. Place the package in those areas which are considered most inaccessible for the sterilizing agent (e.g., the center of the load and areas near the door). Sterilize as usual. After the sterilization process has finished, open the sterilizer door, wait five minutes and remove the SCBI from the package. CAUTION: Wear safety glasses and gloves when removing the Terragene® Bionova® BT224 SCBI from the sterilized package. (Do not crush or handle the SCBI excessively, since this might cause the glass ampoule to burst. Let the SCBI cool down until it reaches room temperature.) 5. Check the Process Indicator on SCBI label. A color change to brown indicates that the SCBI has been exposed to Steam. ( This color change does not evidence the process effectiveness to achieve sterility. If the Process Indicator color has not changed, check the sterilization process.) 6. Press the lid to seal the tube. Crush the ampoule contained in the SCBI with an individual ampoule crusher or with the ampoule crusher placed within the incubator´s incubation area. Then shake the tube down vigorously, with movements similar to those performed to lower the temperature in a mercury thermometer, until the medium reaches the base of the tube and soaks the spore carrier entirely. Finally, place the SCBI in the incubator. 7. Incubate the processed indicator and the positive control indicator in the appropriate Terragene® Bionova® Auto-Reader Incubators for a maximum of 20 minutes at (60 ± 2) °C for ultra rapid readout. Important: Use a non-sterilized SCBI as a positive control at least once per day, when a sterilization cycle is run. The positive control ensures that correct incubation conditions were met; capability of medium to promote rapid growth; viability of spores has not been altered due to improper storage temperature, humidity or proximity to chemicals and proper functioning of Terragene® Bionova® Auto-Reader Incubators. Both, the positive control indicator and the processed indicator, should belong to the same batch. Note: Holding time between sterilization and incubation should not exceed a 7-day period. Fluorescence detection by the reader (excitation 340-380 nm / emission 455-465 nm) means a failure in the sterilization process. If no fluorescence is detected at 20-minute incubation, the result is negative. The positive control must give positive fluorescence readout. It is good practice to incubate a positive control for a visual color change.
SKU: BT224
$290.99 $255.99