Search results for "Sterilization Pouches*"
Medicom Fluff Sponge, 6" x 6¾", Sterile, 2/Pouch, 20 Pouches/Bx, 12Bx/Cs
A highly absorbent primary dressing with softness and bulkiness that surrounds, protects and cushions the wound site. Krimped weave construction with a diamond fold shape that offers cushioning and additional coverage of the wound. Sterile - available in formed plastic trays or pouches. Made of the highest quality fluff dried absorbent cotton.
SKU: A66752
$119.99 $102.99
Medicom Gauze Bandage Roll, 4½" x 4.1 Yds, Sterile 1S, Soft Pouch, 6-Ply, 100/Cs
Gauze Bandage Roll, 4½" x 4.1 yds, Sterile 1s, Soft Pouch, 6-Ply, 100/cs
SKU: A455
$147.99 $129.99
Dynarex Dynarex Sterile Alcohol Prep Pads: Pre-moistened with 70% Isopropyl Alcohol
If you are a medical professional seeking a reliable and effective solution for skin preparation prior to injections or venipunctures, look no further than Dynarex Sterile Alcohol Prep Pads. Our premium single-use pads are pre-moistened with 70% isopropyl alcohol, ensuring rapid-acting antibacterial action to kill germs and bacteria on the skin. With a soft and absorbent non-woven pad, Dynarex Sterile Alcohol Prep Pads are designed to provide maximum absorbency for scrubbing and cleansing. Each pad is sealed in a sterile pouch to prevent dryness and maintain its hygienic properties, giving you peace of mind that the pad is ready for use whenever you need it. At Dynarex, we prioritize safety and reliability. Our Sterile Alcohol Prep Pads are gamma sterilized, guaranteeing that they meet the highest industry standards for sterility. Furthermore, these pads are made without natural rubber latex, ensuring compatibility for users with latex sensitivities. Key Features and Benefits: Pre-moistened with 70% isopropyl alcohol for effective disinfection Soft and absorbent non-woven pad for maximum scrubbing and cleansing By utilizing Dynarex Sterile Alcohol Prep Pads, you can maintain a clean and sterile environment, minimizing the risk of infection for both you and your patients. These pads are essential for any medical professional looking for a dependable and hygienic solution for skin preparation. Don't compromise on quality when it comes to the safety of your patients. Order your box of Dynarex Sterile Alcohol Prep Pads today and experience the difference they can make in your practice.
Medicom Fluff Sponge, 6" x 6¾", Sterile, 10/Hard Tray, 48 Tray/Cs
A highly absorbent primary dressing with softness and bulkiness that surrounds, protects and cushions the wound site. Krimped weave construction with a diamond fold shape that offers cushioning and additional coverage of the wound. Sterile - available in formed plastic trays or pouches. Made of the highest quality fluff dried absorbent cotton.
SKU: A66750
$145.99 $115.99
Medicom Fluff Sponge, 6" x 6¾", Sterile, 5/Hard Tray, 120 Tray/Cs
A highly absorbent primary dressing with softness and bulkiness that surrounds, protects and cushions the wound site. Krimped weave construction with a diamond fold shape that offers cushioning and additional coverage of the wound. Sterile - available in formed plastic trays or pouches. Made of the highest quality fluff dried absorbent cotton
SKU: A66755
$166.99 $135.99
Terragene Steam Chemical Integrator, 250/Bg
IT26-C / Moving front Chemical Integrator to monitor Steam sterilization processes between 118°C and 138°C. Control of Steam sterilization processes between 118 °C and 138 °C. Characteristics: Type 5 Integrating Indicator (according to ISO 11140-1). Size: 52 mm x 21 mm. Chemical Integrator consists of a paper wick and a steam and temperature sensitive chemical pellet contained in a paper/film/foil laminate. The chemical pellet melts and migrates as a dark bar along the paper wick. The migration is visible through a zone marked ACCEPT or REJECT, thus indicating whether sterilization conditions were met. The extent of migration depends on steam quality, time, and temperature. The ACCEPT result is reached when a theoretical spore population reaches its kill time, indicating integration condition has been reached. This condition is calibrated with the kill time of 106 Geobacillus stearothermophilus spore population, calculated in BIER (Biological Indicator Evaluator Resistometer). Conditions: saturated steam at 121 °C, 128 °C, 135 °C. Optionally, the readout of the chemical indicator can be done using Trazanto Automatic Quality Control and Traceability System (see instructions for use in device´s manual). Instructions For Use: Carefully open the package and remove only the number of indicators needed. Reseal the package tightly. Place a Integron® IT26-C indicator in each pack, peel pouch, container system or tray to be steam sterilized in the most inaccessible area to sterilizing agent. Perform de sterilization cycle. After the sterilization process has finished, the dark bar should have reached the ACCEPT zone. If the dark bar has not reached the ACCEPT zone, a REJECT result is indicated and the items in the pack, peel pouch, container system, or tray were not exposed to proper steam sterilization conditions. These items should be reprocessed according to established procedures and a new IT26-C has to be used. Despite this, regarding cycle integration parameters, this process can be considered as accepted. In case the IT26-C indicator shows a damp appearance after the sterilization process, Terragene® recommend planning an equipment´s maintenance. Specifications: Process: Steam Indicator Type: Type 5 chemical indicator Regulations: ISO 11140-1 More Info About This Product: User Manual
SKU: IT26-C
$45.99 $37.99
Terragene Chemical Integrator W/Extender, Steam, Moving Front Type 5, 250/Bg
IT26-C Extender/ Moving front Chemical Integrator to monitor Steam sterilization processes between 118°C and 138°C. Control of Steam sterilization processes between 118 °C and 138 °C. Characteristics: Type 5 Integrating Indicator (according to ISO 11140-1). Size: 52 mm x 21 mm. Chemical Integrator consists of a paper wick and a steam and temperature sensitive chemical pellet contained in a paper/film/foil laminate. The chemical pellet melts and migrates as a dark bar along the paper wick. The migration is visible through a zone marked ACCEPT or REJECT, thus indicating whether sterilization conditions were met. The extent of migration depends on steam quality, time, and temperature. The ACCEPT result is reached when a theoretical spore population reaches its kill time, indicating integration condition has been reached. This condition is calibrated with the kill time of 106 Geobacillus stearothermophilus spore population, calculated in BIER (Biological Indicator Evaluator Resistometer). Conditions: saturated steam at 121 °C, 128 °C, 135 °C. Optionally, the readout of the chemical indicator can be done using Trazanto Automatic Quality Control and Traceability System (see instructions for use in device´s manual). Instructions For Use: Carefully open the package and remove only the number of indicators needed. Reseal the package tightly. Place a Integron® IT26-C indicator in each pack, peel pouch, container system or tray to be steam sterilized in the most inaccessible area to sterilizing agent. Perform de sterilization cycle. 4After the sterilization process has finished, the dark bar should have reached the ACCEPT zone. If the dark bar has not reached the ACCEPT zone, a REJECT result is indicated and the items in the pack, peel pouch, container system, or tray were not exposed to proper steam sterilization conditions. These items should be reprocessed according to established procedures and a new IT26-C has to be used. NOTE: In some extended or wet steam cycles, the dark bar can display discoloration in some zones of the reading window, imposing a difficulty for result´s interpretation (see Result Reference Guide for reference). Despite this, regarding cycle integration parameters, this process can be considered as accepted. In case the IT26-C indicator shows a damp appearance after the sterilization process, Terragene® recommend planning an equipment´s maintenance.
SKU: IT26-C EXT
$40.99 $31.99