Schools & Offices
McKesson Esmark Compression Bandage McKesson 6 Inch X 3 Yard No Closure Blue Sterile High Compression
McKesson Esmark Bandages 6 x 9 feet (15.0 cm x 2.5 m)" Consistent compression. Single Use Not made with natural rubber latex. Packaged: 1 Per Pack, 20 Packs Per Case Manufacturer # 16-50609 Brand McKesson Manufacturer McKesson Brand Country of Origin Malaysia Application Esmark Compression Bandage Closure Type No Closure Color Blue Color Range Blue / Green / Gray Color Compression Rating High Compression Dimensions 6 Inch X 3 Yard Length 1 to 3 Yard Length Material Polyisoprene Sterility Sterile UNSPSC Code 42311506 Width 6 to 7 inch Width Latex Free Indicator Not Made with Natural Rubber Latex
SKU: 16-50609-1
$4.99 - $95.99
McKesson Esmark Compression Bandage McKesson 4 Inch X 3 Yard No Closure Blue Sterile High Compression
McKesson Esmark Bandages 4 x 9 feet (10.0 cm x 2.5 m) Maximum and consistent compression. Minimal powder on surface. Individually wrapped. Sterile Single Use Not made with natural rubber latex. Packaged: 1 Per Pack, 20 Packs Per Case Manufacturer # 16-50409 Brand McKesson Manufacturer McKesson Brand Country of Origin Malaysia Application Esmark Compression Bandage Closure Type No Closure Color Blue Color Range Blue / Green / Gray Color Compression Rating High Compression Dimensions 4 Inch X 3 Yard HCPCS A6219 Length 1 to 3 Yard Length Material Polyisoprene Sterility Sterile UNSPSC Code 42311506 Width 4 Inch Width Latex Free Indicator Not Made with Natural Rubber Latex
SKU: 16-50409-1
$4.99 - $67.99
Cardinal Gauze Sponge Curity 4 X 4 Inch 12-Ply NonSterile 200 per Pack
USP Type VII Well suited for variety of applications; wound dressing, general cleaning, minor prepping, wound packing and debriding WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov BG/200 $10.49 CS/2000 $104.85 McKesson # 10001 Manufacturer # 2634- Brand Curity™ Manufacturer Cardinal Country of Origin China Application Gauze Sponge Color White Dimensions 4 X 4 Inch FSA Eligible - Sell UOM Yes HCPCS A6216 Length Up to 4 Inch Length Material USP Type VII Number per Pack 200 per Pack Ply 12-Ply Shape Square Shape Range Rectangle / Square Grouping Sterility NonSterile UNSPSC Code 42311512 Width 4 Inch Width
SKU: 2634-BG
$12.99 - $116.99
McKesson Surgical Laparotomy Sponge McKesson X-Ray Detectable Cotton 18 X 18 Inch 5 Count Soft Pack Sterile
McKesson Lap Sponges, Prewashed Soft Pack 18 Inch x 18 Inch 100% Cotton X-Ray Detectable Sterile Single Use Not made with natural rubber latex. Packaged: 5 Per Pack, 40 Packs Per Case Manufacturer # 16-2118181 Brand McKesson Manufacturer McKesson Brand Country of Origin China Application Surgical Laparotomy Sponge Color White Dimensions 18 X 18 Inch HCPCS A6402 Material Cotton Number per Pack 5 Count Packaging Type Soft Pack Ply 4-Ply Shape Square Sterility Sterile Type X-Ray Detectable UNSPSC Code 42295406 Latex Free Indicator Not Made with Natural Rubber Latex
SKU: 16-2118181
$2.99 - $92.99
McKesson Surgical Laparotomy Sponge McKesson X-Ray Detectable Cotton 12 X 12 Inch 5 Count Soft Pack Sterile
McKesson Lap Sponges, Prewashed Soft Pack 12 inch x 12 inch 100% Cotton X-Ray Detectable Sterile Single Use Not made with natural rubber latex. Packaged: 5 Per Pack, 40 Packs Per Case Manufacturer # 16-2112121 Brand McKesson Manufacturer McKesson Brand Country of Origin China Application Surgical Laparotomy Sponge Color White Dimensions 12 X 12 Inch Material Cotton Number per Pack 5 Count Packaging Type Soft Pack Ply 4-Ply Shape Square Sterility Sterile Type X-Ray Detectable UNSPSC Code 42295406 Latex Free Indicator Not Made with Natural Rubber Latex
SKU: 16-2112121
$1.99 - $71.99
McKesson Surgical Laparotomy Sponge McKesson X-Ray Detectable Cotton 18 X 18 Inch 5 Count Hard Pack Sterile
McKesson Lap Sponges, Prewashed Rigid Pack 18 inch x 18 inch 100% Cotton X-Ray Detectable Sterile Single Use Not made with natural rubber latex. Packaged: 5 Per Pack, 20 Packs Per Case Manufacturer # 16-2118182 Brand McKesson Manufacturer McKesson Brand Country of Origin China Application Surgical Laparotomy Sponge Color White Dimensions 18 X 18 Inch Material Cotton Number per Pack 5 Count Packaging Type Hard Pack Ply 4-Ply Shape Square Sterility Sterile Type X-Ray Detectable UNSPSC Code 42295406 Latex Free Indicator Not Made with Natural Rubber Latex
SKU: 16-2118182-PK
$2.99 - $63.99
O&M Halyard Inc Paper Towel Kleenex C-Fold
Kleenex® C Fold Paper Towels are designed for single-use general-purpose cleaning and drying The built-in, premium absorbency pockets mean that the commercial towels soak up water fast The C fold towels (sometimes called a tri fold) facilitate stacking and unfolding, and the size is compatible with many universal and C-fold dispensers Manufacturer # 01500 Brand Kleenex® Manufacturer Kimberly Clark Country of Origin Unknown Application Paper Towel Color White Dimensions 10-1/8 X 13-3/20 Inch Material Paper Ply 1-Ply Sheets per Unit 150 Sheets Type C-Fold UNSPSC Code 14111703 Latex Free Indicator Not Made with Natural Rubber Latex
SKU: 01500
$4.99 - $76.99
Procter & Gamble Safeguard Professional Hand Sanitizer, Liquid, 2oz, 48/cs
Safeguard Professional Hand Sanitizer, Liquid, 2oz, 48/cs Alcohol Antiseptic 69.9% Topical Solution Hand application to decrease bacteria on the skin Fresh Clean Scent Also Available: Safeguard Liquid Hand Soap, Washes Away Bacteria with Micellar Deep Cleansing .
SKU: 3700074439
$94.99 $81.99
McKesson Fluff Bandage Roll Cotton 6-Ply 4-1/2 Inch X 4-1/10 Yard Roll Shape Sterile
Gauze Bandage Rolls 4.5" x 4.1 yds. (11.4 cm x 3.7 m), Stretched Sterile 100% Cotton Crinkled cotton pattern adds loft and bulk for added cushioning and wound protection. Fast-wicking and absorbent. Conformable. Use as a primary or secondary dressing. Single Use Not made with natural rubber latex. Packaged: 1 Roll Per Pack, 100 Packs Per Case McKesson # 446051 Manufacturer # 16-4264 Brand McKesson Manufacturer McKesson Brand Country of Origin China Application Fluff Bandage Roll Color White Dimensions 4-1/2 Inch X 4-1/10 Yard HCPCS A6446 Length 4 to 6 Yard Length Material Cotton Number per Pack 1 Per Pack Ply 6-Ply Shape Roll Shape Shape Range Roll Sterility Sterile UNSPSC Code 42311503 Width 4 Inch Width Latex Free Indicator Not Made with Natural Rubber Latex
SKU: 16-4264-1
$3.99 $2.99
Integra Lifesciences Miltex HeliPlug 3/8" x 3/4" Absorbable Collagen Wound Dressing, 10/Box
Introducing the HeliPlug 3/8" x 3/4" Absorbable Collagen Wound Dressing. This innovative wound dressing is designed to revolutionize the way you treat moist or bleeding extraction and biopsy sites. With its hemostatic collagen material derived from bovine tendon, this absorbable dressing is a must-have for dental and medical facilities. What sets our HeliPlug apart is its ability to stabilize blood clots and protect the surface of the wound from further injury. This plays a crucial role in the healing process, ensuring optimal recovery. Made from soft, pliable, and absorbent collagen sponges obtained from bovine deep flexor tendon, our wound dressing is reliable and effective. One of the key features of the HeliPlug is its reabsorption by the body within 2 to 4 weeks after placement. This eliminates the need for additional removal procedures, simplifying the healing process for patients and saving valuable time for medical professionals. Another standout benefit of the HeliPlug is its convenience and ease of use. Each box contains 10 individually packaged plugs, ensuring hygienic and efficient application. The 3/8" x 3/4" size is ideal for a variety of wound sizes, providing versatility and flexibility. For your peace of mind, our HeliPlug is manufactured under the highest quality standards. With a manufacturer code of 62-202 and the trusted brand name of HeliPlug, you can rely on the durability and efficacy of this wound dressing. Product Specifications: Manufacturer Code: 62-202 Brand: HeliPlug Packaging: Box of 10 plugs Size: 3/8" x 3/4" Type: Bovine plug Upgrade your wound treatment protocol with the HeliPlug 3/8" x 3/4" Absorbable Collagen Wound Dressing. Order now and experience the advanced healing properties of this revolutionary product. Please note that this product can only be shipped to Dental/Medical facilities.
SKU: 62-202
$139.74 $109.99
Integra Lifesciences Miltex Absorbable Collagen Dressing HeliCote 3/4 X 1-1/2 Inch Rectangle Sterile 62-201
HeliCote is used to control bleeding and develop blood clots in palatal donor sites and mucosal flaps HeliCote® collagen wound dressing is used to control bleeding, develop blood clots and to protect wound sites in order for the healing process to begin Heli products are all reabsorbed by the body within 10 to 14 days after placement Manufacturer # 62-201 Brand HeliCote Manufacturer Integra Lifesciences Country of Origin United States Application Absorbable Collagen Dressing Color White Dimensions 3/4 X 1-1/2 Inch Length Up to 4 Inch Length Material Collagen Shape Rectangle Sterility Sterile Type Bovine UNSPSC Code 42311607 Width 3/4 Inch Width
SKU: 62-201
$134.25 $119.99
McKesson McKesson Gauze Sponge Woven Cotton Square NonSterile
McKesson Premium Woven Gauze Sponges Packaged: 200 Per Pack, 20 Packs Per Case Non-Sterile 100% cotton. H-fold. Appropriate for wound dressing, cleaning, prepping, or packing. Reduced linting. Single Use Not made with natural rubber latex.
SKU: 44802000-BX
$7.99 - $181.99
Dynarex Dynarex Cotton Tipped Applicators
Dynarex Cotton Tipped Applicators are a must-have for any medical professional or individual needing convenient and reliable wound care, dressing application, and instrument cleaning. With their highly absorbent cotton tips, these applicators provide optimal performance in a range of medical settings. Designed with precision, these applicators offer uniform length and shape for consistent and effective usage. These cotton tipped applicators come in both sterile and non-sterile varieties, providing options to suit different needs. The sterile applicators are packaged in easy-to-use peel-down pouches, ensuring improved hygiene and preventing contamination. On the other hand, the non-sterile applicators are conveniently packed in an autoclavable pouch, making them suitable for sterilization. One of the key features of the Dynarex Cotton Tipped Applicators is their versatility. The applicators are ideally sized for first-aid kits and emergency bags, making them perfect for on-the-go use. Whether you need to clean wounds, apply medication, or clean medical instruments, these applicators are up to the task. Key features and benefits of Dynarex Cotton Tipped Applicators: Highly absorbent cotton tips for efficient wound care and instrument cleaning Available in both sterile and non-sterile varieties, offering options for different requirements Specifications: #4303-4305: Sterile applicators packaged in convenient peel-down pouches for improved hygiene #4301 & #4302: Non-Sterile Applicators in autoclavable pouch #4307: Cotton Tipped Wood Applicators in sealed clear plastic vial ideal for first aid Upgrade your wound care routine with the reliable and versatile Dynarex Cotton Tipped Applicators. Order yours today and experience the convenience and effectiveness of these high-quality applicators.
SKU: 4303
$34.99 - $71.99
Dynarex Wound Closure Strips - Sterile
Introducing our Wound Closure Strips - Sterile, a must-have product for every medical professional or individual seeking effective wound closure. With their superior design and high-quality materials, these adhesive strips ensure secure wound closure and promote rapid healing. Our Wound Closure Strips are crafted from a flexible, non-woven material that offers both durability and comfort. The skin-friendly adhesive used on these strips minimizes the risk of skin shearing or blistering, ensuring a gentle application process and easy removal when necessary. One of the key features of our Wound Closure Strips is their ability to provide a secure closure. Whether it's a small cut, laceration, or surgical incision, these strips adhere firmly to the skin, holding the wound edges together and allowing for the natural healing process to take place. Furthermore, our adhesive strips are designed to allow maximum porosity and vapor transmission, which contributes to the rapid healing of wounds. The breathable nature of the material ensures adequate airflow, preventing excess moisture build-up and creating an optimal environment for tissue regeneration. When it comes to wound closure, trust in the reliability and effectiveness of our Wound Closure Strips. These sterile strips are suitable for various medical applications and are an essential addition to any first aid kit, clinic, or healthcare facility. Flexible, non-woven material for optimal comfort Skin-friendly adhesive to minimize skin shearing or blistering Whether you are a medical professional or an individual in need of wound closure, our Wound Closure Strips - Sterile are the perfect solution. Don't compromise on quality and choose a trusted product that guarantees secure closure and promotes speedy recovery. Flexible, non-woven material Skin-friendly adhesive to minimize skin shearing or blistering Provides secure closure Allows maximum porosity and vapor transmission for rapid healing
SKU: 3521
$129.99 - $149.99
McKesson Wound and Burn Dressing MEDIHONEY Gel Tube Sterile
MEDIHONEY® Gel with Active Leptospermum Honey 0.5 fl. oz. - Packaged: 10 Tubes Per Box, 4 Boxes Per Case 1.5 fl. oz. / 44 mL - Packaged: 12 Tubes Per Case 80% Active Leptospermum Honey with 20% natural gelling agents. Under the supervision of a healthcare professional, MEDIHONEY® GEL WITH ACTIVE LEPTOSPERMUM HONEY dressing provides a moist environment conducive to wound healing and is indicated for non-draining to moderately exuding wounds such as: Diabetic foot ulcers, Leg ulcers (venous stasis ulcers, arterial ulcers and leg ulcers of mixed etiology), Pressure ulcers / sores (partial and full thickness), 1st and 2nd degree partial thickness burns, donor sites, and traumatic and surgical wounds. More viscous formulation with increased stability at the wound site. Optimal for superficial to full thickness wounds. Cleanses and debrides due to its high osmolarity. Helps to lower the wound pH, for an optimal wound healing environment. Sterile Single Use Not made with natural rubber latex. Gel: US patent #11/106473 pending and foreign counterparts granted and pending. MEDIHONEY is a registered trademark of Medihoney Pty Ltd. and used with permission by Derma Sciences, Inc. For more information on MEDIHONEY® please visit www.dermasciences.com/elearning-portal/webinar-series.
SKU: 31805-10
$18.99 - $234.99
Dukal Nonwoven Sponge Clinisorb 4 X 4 Inch 200 per Pack NonSterile 4-ply Square
Rayon/poly blend construction Highly absorbent Multi-purpose sponges ideal for general wound care and applying ointments Virtually non-linting Attributes Brand Name Dukal Size 4" x 4" Ply 4-Ply HCPC Code A6216 Sterile No Weight 6.22085 lbs Packaging Packaging 200/BG, 10 BG/CS Inner Packaging 200/BG Case Packaging 10 BG/CS Total Case Quantity 2000 Inner Packaging Barcode (01)10665973013784 Case Packaging Barcode (01)20665973013781
SKU: 2104-CS
$51.33 $45.83
Corza Medical Bone Wax Surgical Specialties 2.5 Gram
Features The peel-open foil packet is specifically designed for easy dispensing and provides optimum safety and convenience for use in the operating room A sterile mixture of beeswax, paraffin, and isopropyl palmitate, a wax-softening agent Achieves local hemostasis of bone by acting as a mechanical sealant (tamponade) It does not act biochemically and is minimally resorbable For control of bleeding from bone surfaces during surgical operations Brand Surgical Specialties™ Manufacturer Surgical Specialties Country of Origin Mexico Application Bone Wax UNSPSC Code 42311607 Volume 2.5 Gram
SKU: 903
$27.95 - $64.95
McKesson Gauze Sponge Cotton Square Sterile
McKesson Gauze Sponges 2" x 2" (5.1 cm x 5.1 cm), 8-Ply- Packaged: 2 Per Pack, 25 Packs Per Box, 24 Boxes Per Case 3" x 3" (7.6 cm x 7.6 cm), 12-Ply- Packaged: 2 Per Pack, 40 Packs Per Box, 30 Boxes Per Case 4" x 4" (10.2 cm x 10.2 cm), 8-Ply- Packaged: 2 Per Pack, 25 Packs Per Box, 24 Boxes Per Case Sterile 100% cotton. Appropriate for wound dressing, cleaning, prepping, or packing. Reduced linting. Packed in convenient, peelable pouch. Single Use Not made with natural rubber latex.
SKU: 16-42228-1
$0.25 - $199.99
Biofreeze Biofreeze Professional, 32 oz Gel Pump, Green
Biofreeze Professional gel pump is a top-notch solution for quick and efficient pain relief across various conditions. Experience the power of Biofreeze Professional gel pump, designed to provide highly effective short-term pain relief, accelerating your recovery process. Fast-acting relief: Say goodbye to discomfort with the topical application of Biofreeze Professional gel pump, targeting arthritis, muscle aches, joint pain, sprains, strains, and bruises. Paraben-free formula: Rest assured knowing that Biofreeze Professional gel pump contains no parabens or propylene glycol, prioritizing your well-being. Discover the healing properties of menthol, the active ingredient in Biofreeze Professional gel pump, proudly made in the United States by Boxout LLC. Manufacturer # RKT3209982 Brand Biofreeze® Professional Manufacturer Boxout LLC Country of Origin United States Active Ingredients Menthol Application Topical Pain Relief Container Type Pump Bottle Dosage Form Topical Gel FSA Eligible - Primary UOM Yes Product Dating McKesson Acceptable Dating: we will ship >= 180 days Strength 5% Strength UNSPSC Code 51273800 Volume 32 oz.
SKU: 13429
$59.99 $42.99
Puritan Medical Products Swabstick Puritan Cotton Tip Wood Shaft NonSterile 1000 per Pack
General cleaning Ideal for hard-to-reach areas Tapered mini cotton head 100 per Bag Manufacturer Puritan Medical Products Country of Origin United States Application Swabstick Number per Pack 1000 per Pack Shaft Material Wood Shaft Sterility NonSterile Tip Material Cotton Tip UNSPSC Code 42141504
SKU: 823-WC-BX
$17.99 - $249.99
Unilever Swabstick Q-Tip Cotton Tip Cotton Shaft 3 Inch NonSterile 375 per Pack
The versatile ultimate beauty tool for safely and precisely applying, blending, touching up and removing cosmetics Perfect for use on even the most sensitive areas of the face and body Brand Q-Tip® Manufacturer Unilever Country of Origin Unknown Application Swabstick Length 3 Inch NDC Number 30521516328 Number per Pack 375 per Pack Shaft Material Cotton Shaft Sterility NonSterile Tip Material Cotton Tip Tip Type Double End Tip UNSPSC Code 42141500
SKU: 30521516328
$4.99 - $5.99
McKesson Swabstick McKesson Cotton Tip Wood Shaft NonSterile 100 per Pack
McKesson Cotton-Tipped Applicators Non-Sterile 3 inch (8 cm) Wood Shaft Single Use Not made with natural rubber latex. Packaged: 100 Per Bag, 10 Bags Per Box, 10 Boxes Per Case Manufacturer McKesson Brand Country of Origin China Application Swabstick FSA Eligible - Buy UOM Yes FSA Eligible - Sell UOM Yes HCPCS A4248 Number per Pack 100 per Pack Shaft Material Wood Shaft Sterility NonSterile Tip Material Cotton Tip UNSPSC Code 42141504 Latex Free Indicator Not Made with Natural Rubber Latex
SKU: 24-103-BX
$1.99 - $86.99
Micro Scientific Industries Opti-Cide3 Surface Disinfectant Cleaner Broad Spectrum Manual Pour Liquid 24 oz. Bottle Alcohol Scent NonSterile
A ready-to-use low alcohol dual chain quat disinfectant Effectively and quickly loosens and suspends blood and bodily fluids, non-organic and organic soil, and other cellular debris for easy removal Will effectively sanitize environmental surfaces with a 10-second contact time and disinfect environmental and equipment surfaces with a 2-minute contact time Manufacturer Micro Scientific Industries Country of Origin United States Active Ingredients Isopropyl Alcohol / 2-Butoxyethanol / N-Alkyl Dimethyl Benzyl Ammonium Chloride / N-Alkyl Dimethyl Ethylbenzyl Ammonium Chloride Application Surface Disinfectant Cleaner Container Type Bottle Dispensing Method Manual Pour Form Liquid Product Dating McKesson Acceptable Dating: we will ship >= 180 days Scent Alcohol Scent Sterility NonSterile Type Broad Spectrum UNSPSC Code 42281704 Volume 24 oz.
SKU: NEMSI24
$99.99
MARK3 Self Seal Sterilization Pouches by MARK3
Self Sealing Sterilization Pouches by MARK3 have built-in, easy to read, color changing internal indicators for steam and EiO gas. They are made with self-seal adhesive strips and triple sealed seams to keep out contaminants and maintain the sealed pouch within.Contains: 200/bx Product Specifications MARK3 Self Sealing Sterilization Pouches 200/bx Sterilization pouches are ideal for sterilizing medical, dental and tattoo instruments. Each pouch has two (2) large built-in indicators for steam and EiO Gas which will change color when the optimum temperature is reached. They are made with self-seal adhesive strips and triple-sealed seams to keep out contaminants and maintain the sealed pouch within.
SKU: 100-6120
$4.29 - $57.85
MARK3 MARK3 Self Sealing Sterilization Pouches 200/bx
Self Sealing Sterilization Pouches by MARK3 have built-in, easy to read, color changing internal indicators for steam and EiO gas. They are made with self-seal adhesive strips and triple sealed seams to keep out contaminants and maintain the sealed pouch within.Contains: 200/bx Product Specifications MARK3 Self Sealing Sterilization Pouches 200/bx Sterilization pouches are ideal for sterilizing medical, dental and tattoo instruments. Each pouch has two (2) large built-in indicators for steam and EiO Gas which will change color when the optimum temperature is reached. They are made with self-seal adhesive strips and triple-sealed seams to keep out contaminants and maintain the sealed pouch within.
SKU: 100-6121
$60.99 $57.85
Crosstex In-Office Dry Block Incubator (non-digital), Grey
In-office system for monitoring steam sterilizers. Easy to use and interpret. Results in just 10 hours. Simply process vial in a normal sterilizer cycle. Then activate vial, incubate and record results. If any spores survive the process, the indicator media will turn yellow.
SKU: NDB601
$293.99 $233.99
Crosstex 10 Hour Steam Biological Indicators, 25/bx
Steam Biological Indicators 25/Pk. A breakthrough in biological monitoring - results in just 10 hours. Indicators containing bacterial spores are processed in a normal sterilizer cycle then placed in an incubator. Easy-to-read results are available in 10 hours.
SKU: C10BI25
$159.99 $106.99
Crosstex 10 Hour Office Kit
In-office system for monitoring steam sterilizers. Easy to use and interpret. Results in just 10 hours. Simply process vial in a normal sterilizer cycle. Then activate vial, incubate and record results. If any spores survive the process, the indicator media will turn yellow.
SKU: C10SK
$589.99 $488.99
Crosstex Crosstex Dental Barrier Film, 4" x 6", 1200 sheets/rl
Film, 4" x 6", 1200 sheets/rl, 8 rl/cs
SKU: BFBL
$208.99 $179.99
Terragene Thermal Paper Roll For Minibio, 3Rl/Bg
ICTP Mini / Thermal Paper specially designed for using with Bionova® Mini Bio, Bionova® Mini Pro Auto-Reader€™s Printer.Thermal Paper specially designed for using with Bionova® Mini Bio, Bionova® Mini Pro Auto-Reader€™s Printer. Specifications: Thermal Paper Roll. Color: White Paper Length: 4.7 m. Paper Width: 57 mm. Roll External Diameter: 23 mm. Roll Internal Diameter: 13.4 mm. Its function is to record the final results of biological indicators subjected to sterilization process and quantitative analysis of hygiene monitoring systems at each activated position of Bionova® Mini Bio and Mini Pro incubators, which allows record keeping in your sterilization records book. Read Bionova® Mini Bio and Mini Pro directions for use, as appropriate.
SKU: ICTP MINI
$40.99 $30.99
Terragene Thermal Paper Roll For IC10/20FR And IC10/20FRLCD, 6rl/Bg
ICTP / Incubator Thermal Paper. Accessory for the IC10/20FR and IC10/20FRLCD incubator€™s thermal printer. Thermal Paper specially designed for using with Bionova® IC10/20FR, and Bionova® IC10/20FRLCD Auto-Reader€™s Printer. Specifications: Thermal Paper Roll. Color: white Paper length: 30 m. Paper width: 57 mm. Roll external diameter: 50 mm. Roll internal diameter: 13.4 mm. Its function is to record the final results of biological indicators subjected to sterilization process and quantitative analysis of hygiene monitoring systems at each activated position of IC10/20FR or IC10/20FRLCD, which allows registration into your sterilization record keeping book. Read IC10/20FR or IC10/20FRLCD directions for use, as appropriate.
SKU: ICTP_BION_6
$50.99 $37.99
Terragene Strip Integrator Steam, 500/Bg
Multi-variable Chemical Indicator printed with reactive ink for Steam sterilization processes. Chemdye® CD29 Multivariable Process Indicators (Type 4 according to ISO 11140-1:2014 standard) are single-use chemical indicators that consist of one-side laminated punched paper double strips printed with indicator ink. These indicators have been designed to monitor Steam sterilization processes within loads, ensuring an adequate exposure to the sterilizing agent during the sterilization process and allowing to distinguish between processed and unprocessed items. Innovative highly sensitive yellow ink was developed to turn to dark brown/black when the indicator is exposed to Steam considering the critical process variables which provides additional quality assurance. Endpoint condition: 121 °C, 15 minutes; 134 °C, 3.5 minutes. Indicators 100 % free of toxic heavy metals. Instructions For Use: Place a Chemdye® CD29 Multivariable Process Indicator within each package, bag or tray that will be sterilized by Steam. In rigid containers, place the indicator in every corner, or at least two diagonally opposite corners, to ensure that the sterilization agent has reached the most inaccessible areas. Perform the sterilization cycle. After the sterilization process has finished, remove the indicators from the sterilizer and analyze the results. For all the chemical indicators exposed to Steam, the ink must turn to the dark brown/black reference color when the sterilization parameters are reached. For reference color, please refer to Result Reference Guide. Specifications: Process: Steam Initial Color: Yellow Final Color; Black Indicator Type: Type 4 chemical indicator Regulations: ISO 11140-1 More Info About This Product: Color Chart
SKU: CD29
$15.99 $12.99
Terragene Strip Integrator EO, 500/Bg
CD16 / Multi-variable Chemical Indicators, double card strips printed with reactive ink for Ethylene Oxide sterilization processes. Metals Free. Control of Ethylene Oxide (EO) sterilization processes. Conditions: 600 mg/l EO, RH 60%, 30 °C, 30 minutes // 600 mg/l EO, RH 60%, 54 °C, 20 minutes. Characteristics: Type 4 Chemical Indicator (according to ISO 11140-1). Double punched card strips printed with indicator ink. Specifications: Size: 200 x 15 mm. Initial Color: Purple/Brown. Final Color: Green. 100 % Toxic Heavy Metals free. Instructions For Use: Place a Chemdy® CD16 Multivariable Process Indicator within each package, bag or tray that will be sterilized by Ethylene Oxide. In rigid containers, place the indicator in every corner, or at least two diagonally opposite corners, to ensure mthat the sterilization agent has reached the most inaccessible areas. Perform the sterilization cycle. After the sterilization process has finished, remove the indicators from the sterilizer and analyze the results. For all the chemical indicators exposed to Ethylene Oxide, the ink must turn to the green reference color when the sterilization parameters are reached. More Info About This Product: Color Chart
SKU: CD16
$20.99 $15.90
Terragene PCD, Ultra Rapid W/BI (20Min) For Steam, 25 Bis + 25 PCDs/Kt
KPCD224-C / Test Pack PCD Kit. Process Challenge Device for Steam sterilization processes with moving-front Type 5 Integrator and Bionova® Ultra Rapid Self-contained Biological Indicator BT224, plus Bionova® BT224 Biological Indicators Positive Control. Class 5 spores per strip. For routine load release, especially for loads containing implants. For routine sterilizer monitoring. For periodic validation of the sterilizer (after installation, repair, relocation). Detects inadequate air removal and steam penetration in dynamic- airremoval (pre-vacuum) and gravity displacement, steam autoclaves between 132-135 ºC. Characteristics: The kit Consists Of: PCD224-C: Porous Cards System Holding: A Self-contained Biological Indicator Bionova® BT224.A Type 5 chemical indicator Integron® IT26-C (moving-front integrator). A self-adhesive Record Card, PCDBI-C-RC, where data on sterilization cycle may be written. Self-contained Biological Indicator Bionova® BT224 (to be used as a positive control) Specifications: Initial Color: Blue. Final Color: Dark Grey or Black. Process: Steam Microorganism: Geobacillus stearothermophilus (ATCC 7953) Population: 10^6 Spores/carrier Read-Out Time: 20 min Regulations: ANSI/AAMI ST79, ISO 11138-3, ISO 11140-1 IT26-C Integrator Indicator (within the challenge device): The migration is visible through a zone marked ACCEPT or REJECT, thus indicating whether sterilization conditions were met. Integration condition is calibrated against the kill time of a 106 G. stearothermophilus ATCC 7953 spore population, calculated in BIER (Biological Indicator Evaluator Resistometer). Conditions: saturated steam at 121 ºC, 128 ºC, 135 ºC. BT224 Self-contained Ultra Rapid Biological Indicator (within the challenge device): 106 G. stearothermophilus ATCC 7953 spores per vial in paper carrier. Glass ampoule with growth indicator medium. Label with chemical indicator line printed with Steam reactive ink (Color change: pink to brown) Final results: by fluorescence after incubation for 20 minutes at 60 ºC (sensitivity 97%). An optional visual pH color change confirmation could be made after 48 hours of incubation. A 7-day readout is optional to confirm 20-minutes results by color change. Note: If sterilization process was not successful, indicator medium will turn yellow after incubation, thus indicating the presence of living G. stearothermophilus spores. If sterilization process was successful, indicator medium will remain purple after incubation.
SKU: KPCD224-C
$260.99 $220.99
Terragene PCD Kit For Steam With BI (1h), IT26-C Integrator Indicator, 25 Bis + 25 PCD/Kt
KPCD222-C / Test Pack PCD Kit. Process Challenge Device for Steam sterilization processes with moving-front Type 5 Indicator and Bionova® Super Rapid Self-contained Biological Indicator BT222, plus Bionova® BT222 Biological Indicators Positive Control. For routine load release, especially for loads containing implants. For routine sterilizer monitoring. For periodic validation of the sterilizer (after installation, repair, relocation). Detects inadequate air removal and steam penetration in dynamic-airremoval (pre-vacuum) and gravity displacement steam autoclaves between 121-135 ºC. Characteristics: The Kit Consists Of: PCD222-C: Porous cards system holding: A Self-contained Biological Indicator Bionova® BT222. A Type 5 chemical indicator Integron® IT26-C (moving-front integrator). A self-adhesive Record Card, PCDBI-C-RC, where data on sterilization cycle may be written. Self-contained Biological Indicator Bionova® BT222 (to be used as a positive control) Specifications: Initial Color: Blue Final Color: Dark Grey or Black Process: Steam Microorganism: Geobacillus stearothermophilus (ATCC 7953) Population: 10^6 Spores/carrier Read-Out Time: 1 h Regulations: ANSI/AAMI ST79, ISO 11138-1, ISO 11138-3 IT26-C Chemical Integrator (within the challenge device) The migration is visible through a zone marked ACCEPT or REJECT, thus indicating whether sterilization conditions were met. Integration condition is calibrated against the kill time of a 106 G. stearothermophilus ATCC 7953 spores€™ population, calculated in BIER (Biological Indicator Evaluator Resistometer). Conditions: saturated steam at 121 °C, 128 °C, 135 °C. BT222 Super Rapid Self-contained Biological Indicator (within the challenge device): ‰¥106 G. stearothermophilus ATCC 7953 spores per vial in paper carrier. Glass ampoule with growth indicator medium. Label with chemical indicator line printed with Steam reactive ink (Color change: pink to brown)
SKU: KPCD222-C
$240.99 $205.99
Terragene Steam Indicator Tape Roll
CT22 / Indicator Tape for Steam sterilization processes. Cintape® CT22 Process Indicators (Type 1 according ISO 11140-1:2014 standard) are single-use chemical indicators that consist of a roll of self-adhesive paper tape printed with indicator ink. These indicators have been designed to monitor Steam sterilization processes, ensuring an adequate exposure to the sterilizing agent during the sterilization process and allowing to distinguish between processed and unprocessed items. The adhesive component of the tape allows the adhesion to different types of packaging and wraps, such as cloth, paper and plastic being easy to remove and leaving no residues. Innovative highly sensitive yellow ink was developed to turn to dark brown / black when the indicator is exposed to Steam. Endpoint condition: 121 ºC, 10 minutes; 134 ºC, 2 minutes. Instructions For Use: Place within a sterilizer a wrapped package closed with Cintape® CT22 Process Indicator tape that will be sterilized by Steam. Perform the sterilization cycle. After the sterilization process has finished, remove the package from the sterilizer and analyze the indicator results. The indicator must turn to the reference color for considering that it was exposed to Steam. For reference color, please refer to Result Reference Guide. Specifications: Process: Steam Initial Color: Yellow Final Color: Black, Dark Brown Indicator Type: Type 1 chemical indicator Regulations: ISO 11140-1 More Info About This Product: Color Chart
SKU: CT22
$5.99 $4.99
Terragene Hydrogen Peroxide Indicator Tape
Indicator Tape for Plasma or Vaporized Hydrogen Peroxide Sterilization Processes. Cintape® CT40 Process Indicators (Type 1 according ISO 11140-1:2014 standard) are single-use chemical indicators that consist of a roll of self-adhesive plastic tape printed with indicator ink. These indicators have been designed to monitor Plasma or Vaporized Hydrogen Peroxide sterilization processes, ensuring adequate exposure to the sterilizing agent during the sterilization process and allowing to distinguish between processed and unprocessed items. The adhesive component of the tape allows the adhesion to different types of packaging and wraps, such as cloth, paper and plastic being easy to remove and leaving no residues. Innovative highly sensitive purple ink was developed to turn to green when the indicator is exposed to Plasma or Vaporized Hydrogen Peroxide. Endpoint condition: 50 ºC, 6 minutes, 2.3 mg/l H2O2. Indicators 100 % free of toxic heavy metals. Instructions For Use: Place within a sterilizer a wrapped package closed with Cintape® CT40 Process Indicator tape that will be sterilized by Plasma or Vaporized Hydrogen Peroxide. Perform the sterilization cycle. After the sterilization process has finished, remove the package from the sterilizer and analyze the indicator results. The indicator must turn to the reference color for considering that it was exposed to Plasma or Vaporized Hydrogen Peroxide. For reference color, please refer to Result Reference Guide. Specifications: Process: Hydrogen Peroxide Initial Color: Purple Final Color: Green Indicator Type: Type 1 chemical indicator Regulations: ISO 11140-1
SKU: CT40
$18.99 $14.99
Terragene Fluorescence Ultra Rapid SCBI For H2O2. 60°C (30 minutes), 50/Bx
Super Rapid Self-contained Biological Indicator for Plasma or Vaporized Hydrogen Peroxide Sterilization Processes. Final readout: 30 minutes. An optional visual pH color change confirmation could be performed after 48 hours of incubation. If sterilization process has not been successful, culture medium will change to yellow during incubation at 60 ºC, thus showing the presence of living spores. If sterilization process is successful culture medium will remain purple after the incubation process. 7-day readout is optional and not intended to be routinely performed; it is an initial validation of the 30-minute reading. Fluorescence results may be compared to the 7-day visual reading. Note: If 7-day readout is performed, a humidified environment will be required to prevent medium from drying out. Instructions For Use: Identify the Terragene® Bionova® BT96 SCBI by writing the sterilizer number (in case of having more than one), load number and processing date on the label. Pack the SCBI along with materials to be sterilized in an appropriate package according to recommended sterilization practices. Place the package in those areas which are considered most inaccessible for the sterilizing agent (e.g., the center of the load and areas near the door). Sterilize as usual. After the sterilization process has finished, open the sterilizer door, wait five minutes and remove the SCBI from the package. CAUTION: Wear safety glasses and gloves when removing the Terragene® Bionova® BT96 SCBI from the sterilized package.( Do not crush or handle the SCBI excessively, since this might cause the glass ampoule to burst. Let the SCBI cool down until it reaches room temperature.) Check the Process Indicator on SCBI label. A color change to green indicates that the SCBI has been exposed to Hydrogen Peroxide. IMPORTANT: This color change does not evidence the process effectiveness to achieve sterility. If the color of the Process Indicator has not changed, check the sterilization process. 6. Press the lid to seal the tube. Crush the ampoule contained in the SCBI with an individual ampoule crusher or with the ampoule crusher placed within the incubator´s incubation area. Then shake the tube down vigorously, with movements similar to those performed to lower the temperature in a mercury thermometer, until the medium reaches the base of the tube and soaks the spore carrier entirely. Finally, place the SCBI in the incubator. Incubate the processed indicator and the positive control indicator in the appropriate Terragene® Bionova® Auto-Reader incubators for a maximum of 30 minutes at (60 ± 2) °C for super rapid readout. Important: Use a non-sterilized SCBI as a positive control at least once per day, when a sterilization cycle is run. The positive control ensures that correct incubation conditions were met; the capability of the medium to promote rapid growth; viability of spores has not been altered due to improper storage temperature, humidity or proximity to chemicals and proper functioning of Terragene® Bionova® Auto-Reader Incubators. Both, the positive control indicator and the processed indicator, should belong to the same batch. Note: Holding time between sterilization and incubation should not exceed a 7-day period. Fluorescence detection by the reader (excitation 340-380 nm / emission 455-465 nm) means failure in the sterilization process. If no fluorescence is detected after 30 minutes of incubation, the result is negative. The positive control must give positive fluorescence readout. It is good practice to incubate a positive control for visual color change. Specifications: Process: Hydrogen peroxide Microorganism: Geobacillus stearothermophilus (ATCC 7953) Population: 10^6 Spores/carrier Read-Out Time: 30 min Regulations: IRAM 37102-1, ISO 11138-1
SKU: BT96
$390.99 $315.99
Terragene Fluorescence SCBI For Steam. 60°C (20 minutes), Ultra Rapid, 50/bx
Ultra Rapid Self-contained Biological Indicator for Steam sterilization processes. Geobacillus stearothermophilus (ATCC 7953) 10^6 spores per vial. Readout: 20 minutes. An optional visual pH color change confirmation could be made after 48 hours of incubation. If the sterilization process has not been successful, the culture medium will change to a greenish color first, and then to yellow during incubation at 60 ºC, thus showing the presence of living spores. If the sterilization process is successful culture medium will remain purple after the incubation process. 7-day readout is optional and not intended to be routinely performed; it is an initial validation of the 20 minute-reading. Fluorescence results may be compared to the 7-day visual reading. Note: If 7-day readout is performed, a humidified environment will be required to avoid medium to dry out. D-Value: Not lower than 1.5 minutes at 121 ºC. Another D-value is informed at 132ºC and at 135ºC. Z-Value is informed. Instructions For Use: Identify the Terragene® Bionova® BT224 SCBI by writing the sterilizer number (in case of having more than one), load number and processing date on the label. Pack the SCBI along with materials to be sterilized in an appropriate package according to recommended sterilization practices. Place the package in those areas which are considered most inaccessible for the sterilizing agent (e.g., the center of the load and areas near the door). Sterilize as usual. After the sterilization process has finished, open the sterilizer door, wait five minutes and remove the SCBI from the package. CAUTION: Wear safety glasses and gloves when removing the Terragene® Bionova® BT224 SCBI from the sterilized package. (Do not crush or handle the SCBI excessively, since this might cause the glass ampoule to burst. Let the SCBI cool down until it reaches room temperature.) 5. Check the Process Indicator on SCBI label. A color change to brown indicates that the SCBI has been exposed to Steam. ( This color change does not evidence the process effectiveness to achieve sterility. If the Process Indicator color has not changed, check the sterilization process.) 6. Press the lid to seal the tube. Crush the ampoule contained in the SCBI with an individual ampoule crusher or with the ampoule crusher placed within the incubator´s incubation area. Then shake the tube down vigorously, with movements similar to those performed to lower the temperature in a mercury thermometer, until the medium reaches the base of the tube and soaks the spore carrier entirely. Finally, place the SCBI in the incubator. 7. Incubate the processed indicator and the positive control indicator in the appropriate Terragene® Bionova® Auto-Reader Incubators for a maximum of 20 minutes at (60 ± 2) °C for ultra rapid readout. Important: Use a non-sterilized SCBI as a positive control at least once per day, when a sterilization cycle is run. The positive control ensures that correct incubation conditions were met; capability of medium to promote rapid growth; viability of spores has not been altered due to improper storage temperature, humidity or proximity to chemicals and proper functioning of Terragene® Bionova® Auto-Reader Incubators. Both, the positive control indicator and the processed indicator, should belong to the same batch. Note: Holding time between sterilization and incubation should not exceed a 7-day period. Fluorescence detection by the reader (excitation 340-380 nm / emission 455-465 nm) means a failure in the sterilization process. If no fluorescence is detected at 20-minute incubation, the result is negative. The positive control must give positive fluorescence readout. It is good practice to incubate a positive control for a visual color change.
SKU: BT224
$290.99 $255.99
Terragene Fluorescence Hyper Rapid SCBI For H2O2. 60°C (5 minutes), 50/Bx
Hyper Rapid Self-contained Biological Indicator for Vaporized Hydrogen Peroxide sterilization processes. Final readout: 5 minutes. Indications For Use: Terragene® Bionova® BT98 fluorescence hyper rapid readout Biological Indicators have been designed for quick and easy monitoring of Plasma or vaporized hydrogen Peroxide sterilization cycles. Device Description: Terragene® Bionova® BT98 fluorescence hyper rapid readout Biological Indicators are single-use Self-Contained Biological Indicators (SCBIs) that consist of a polypropylene tube, a spore carrier and a glass ampoule with a culture medium, enclosed with a colored cap. Each tube contains a population of Geobacillus stearotermophilus ATCC 7953 spores inoculated on a spore carrier, a plastic cap with holes and a barrier permeable to Plasma or Vaporized Hydrogen Peroxide. Each BT98 has a Process Indicator on label that changes from purple to green when exposed to hydrogen peroxide. Precautions: Warning: Do not use Terragene® Bionova® BT98 SCBI to control EO, Dry Heat, Formaldehyde or other sterilization processes different from specified. Do not reuse SCBI. Warning: Place one or more SCBI in sterilizing hard-to-reach areas to ensure all areas of the chamber are sterilized. Please evaluate all load configurations to ensure ALL hard-to-reach areas have been identified, and place a SCBI in each of those locations. Warning: Do not reuse the sterilizer until the SCBI test result is negative. Instructions For Use: Identify the Terragene® Bionova® BT98 SCBI by writing the sterilizer number (incase of having more than one), load number and processing date on the label. Pack the SCBI along with materials to be sterilized in an appropriate package according to recommended sterilization practices. Place the package in those areas which are considered most inaccessible for the sterilizing agent (e.g., the center of the load and areas near the door). Sterilize as usual. After the sterilization process has finished, open the sterilizer door, wait five minutes and remove the SCBI from the package. Caution Wear safety glasses and gloves when removing the Terragene® Bionova® BT98 SCBI from the sterilized package. ( Do not crush or handle the SCBI excessively, since this might cause the glass ampoule to burst. Let the SCBI cool down until it reaches room temperature.) Check the Process Indicator on SCBI label. A color change to green indicates that the SCBI has been exposed to Hydrogen Peroxide. IMPORTANT: This color change does not evidence the process effectiveness to achieve sterility. If the color of the Process Indicator has not changed, check the sterilization process. Press the lid to seal the tube. Crush the ampoule contained in the SCBI with an individual ampoule crusher or with the ampoule crusher placed within the incubator´s incubation area. Then shake the tube down vigorously, with movements similar to those performed to lower the temperature in a mercury thermometer, until the medium reaches the base of the tube and soaks the spore carrier entirely. Finally, place the SCBI in the incubator. Incubate the processed indicator and the positive control indicator in the appropriate Terragene® Bionova® auto-reader incubators for a maximum of 5 minutes at (60 ± 2) °C for hyper rapid readout. (Holding time between sterilization and incubation should not exceed a 1-hour period.) Important: Use a non-sterilized SCBI as a positive control at least once per day, when a sterilization cycle is run. The positive control ensures that correct incubation conditions were met; the capability of the medium to promote rapid growth; viability of spores has not been altered due to improper storage temperature, humidity or proximity to chemicals and proper functioning of Terragene® Bionova® Auto-Reader Incubators. Both, the positive control indicator and the processed indicator, should belong to the same batch. Fluorescence detection by the reader (excitation 340-380 nm / emission 455-465 nm) means failure in the sterilization process. If no fluorescence is detected after 5 minutes of incubation, the result is negative. The positive control must give positive fluorescence readout. It is good practice to incubate a positive control for visual color change. Record positive results and discard the SCBIs immediately, as it is indicated below. Hyper Rapid Readout: 5 minutes The hyper rapid readout must be carried out in the appropriate Terragene® Bionova® auto-reader incubators. Fluorescence is emitted after the reader stimulates the spore carrier with UV light. Final readout of negative results is readily available after 5 minutes of incubation. Fluorescence readout is an indirect measure of the viability of Geobacillus stearothermophilus spores after the sterilization process (positive results). Furthermore, a failure in the sterilization process can also become evident by culture medium color-change. Due to the high sensitivity of the fluorescence results at 5 minutes, conventional incubation for color change of Terragene® Bionova® SCBI BT98 is not an advantage. Visual Confirmation: 5 days: Optionally, you can perform a visual color-change confirmation after a 5-day incubation. If the sterilization process has not been successful, culture medium will turn to yellow during incubation at (60 ± 2) ºC, indicating the presence of living spores. If sterilization was successful, culture medium will remain purple after incubation. The positive control must show a color change from purple to yellow for results to be valid. ( If 5-day readout is performed, a humidified environment will be required to prevent medium from drying out.) Readout Time: 7 days A 7-day readout is optional and may be routinely performed. This is an initial validation of the 5-minute readout. Fluorescence results are compared to the 7-day visual readouts. Monitoring Frequency: Follow facility policies and procedures which should specify a biological indicator monitoring frequency compliant with professional association recommended practices and/or national guidelines and standards. As the best practice and to provide optimal patient safety, Terragene® recommends that every sterilization load be monitored with an appropriate biological indicator. Storage: Store in a dark place at temperature between 10-30 ºC and 30-80 % relative humidity. Do not freeze. Do not store biological indicators near sterilizing agents or other chemical products. Shelf Life: Biological Indicators have an expiration date of 2 years from the date of manufacture when stored at recommended conditions. Do not use indicators after their expiration date. Chemical Process Indicator on SCBI label have an expiration date of 2 years when used as part of SCBI. Endpoint Stability Reaction: Chemical Process Indicator endpoint shall remain unchanged for a period of 6 months when stored at previously indicated conditions. Disposal: Discard biological indicators after use according to your country’s healthcare and safety regulations. The positive biological indicators can be autoclaved in a gravity air displacement steam sterilizer at 121 ºC for 5 minutes, 132 ºC for 15 minutes or 134 ºC for 10 minutes; or in a dynamic air removal steam sterilizer at 132 °C for 4 minutes or 135 °C for 3 minutes. Specifications: Population: 10^6 Spores/carrier Read-Out Time: 5 min Regulations: IRAM 37102-1:1999, ISO 11138-1:2017, ISO 13485:2016 / NS-EN ISO 13485:2016
SKU: BT98
$590.99 $510.99
Terragene Fluorescence SCBI For EO, 37°C (4 hour), 50/Bx
Rapid Self-contained Biological Indicator for Ethylene Oxide sterilization processes. Bacillus atrophaeus (ATCC 9372) 10^6 spores per vial. Readout: 4 hours. An optional visual pH color change confirmation could be made after 48 hours of incubation. If sterilization process has not been successful, culture medium will change to a greenish color first, and then to yellow during incubation at 37 ºC, thus showing the presence of living spores. If sterilization process is successful culture medium will remain blue after the incubation process. 7-day readout for visual confirmation by color change is optional and not intended to be routinely performed; it is an initial validation of the 4 hour-reading. Fluorescence results may be compared to the 7-day visual reading. Instructions For Use: Identify the Terragene® Bionova® BT110 SCBI by writing the sterilizer number (in case of having more than one), load number and processing date on the label. Pack the SCBI along with materials to be sterilized in an appropriate package according to recommended sterilization practices. Place the package in those areas which are considered most inaccessible for the sterilizing agent (e.g., the center of the load and areas near the door). Sterilize as usual. After the sterilization process has finished, open the sterilizer door, wait five minutes and remove the SCBI from the package. CAUTION: Wear safety glasses and gloves when removing the Terragene® Bionova® BT110 SCBI from the sterilized package. Check the Process Indicator on SCBI label. A color change to green indicates that the SCBI has been exposed to Ethylene Oxide. IMPORTANT: This color change does not evidence the process effectiveness to achieve sterility. If the color of the Process Indicator has not changed, check the sterilization process. Press the lid to seal the tube. Crush the ampoule contained in the SCBI with an individual ampoule crusher or with the ampoule crusher placed within the incubator´s incubation area. Then shake the tube down vigorously, with movements similar to those performed to lower the temperature in a mercury thermometer, until the medium reaches the base of the tube and soaks the spore carrier entirely. Finally, place the SCBI in the incubator. Incubate the processed indicator and the positive control indicator in the appropriate Terragene® Bionova® Auto-Reader incubators for a maximum of 4 hours at (37 ± 2) °C for rapid readout. Note: Holding time between sterilization and incubation should not exceed a 7-day period. Fluorescence detection by the reader (excitation 340-380 nm / emission 455-465 nm) means failure in the sterilization process. If no fluorescence is detected after 4 hours of incubation, the result is negative. The positive control must give positive fluorescence readout. It is good practice to incubate a positive control for visual color change. If chamber relative humidity is unknown or < 35 %, continue to incubate the Biological Indicator for a pH color change result, since low relative humidity may increase the fluorescent readout time beyond 4 hours. Specifications: Process: Ethylene Oxide Microorganism: Bacillus atrophaeus (ATCC 9372) Population: 10^6 Spores/carrier Read-Out Time: 4 h Regulations: IRAM 37102-1, IRAM 37102-2, ISO 11138-1, ISO 11138-2 Length: 40 mm
SKU: BT110
$250.99 $210.99
Terragene Fluorescence SCBI For Steam, 60°C (1h), 50/Bx
Super Rapid Self-contained Biological Indicator for Steam sterilization processes. Geobacillus stearothermophilus (ATCC 7953) 10^6 spores per vial. Readout: 1 hour. An optional visual pH color change confirmation could be made after 48 hours of incubation. If sterilization process has not been successful, culture medium will change to a greenish color first, and then to yellow during incubation at 60 ºC, thus showing the presence of living spores. If sterilization process is successful culture medium will remain purple after the incubation process. 7-day readout is optional and not intended to be routinely performed; it is an initial validation of the 1 hour-reading. Fluorescence results may be compared to the 7-day visual reading. Note: if 7-day readout is performed, a humidified environment will be required to avoid medium to dry out. D-Value: Not lower than 1.5 minutes at 121 ºC. Another D-value is informed at 132 ºC and at 135 ºC. Z-Value is informed. Instructions For Use: Identify the Terragene® Bionova® BT222 SCBI by writing the sterilizer number (in case of having more than one), load number and processing date on the label. Pack the SCBI along with materials to be sterilized in an appropriate package according to recommended sterilization practices. Place the package in those areas which are considered most inaccessible for the sterilizing agent (e.g., the center of the load and areas near the door). Sterilize as usual. After the sterilization process has finished, open the sterilizer door, wait five minutes and remove the SCBI from the package. CAUTION: Wear safety glasses and gloves when removing the Terragene® Bionova® BT222 SCBI from the sterilized package. WARNING: Do not crush or handle the SCBI excessively, since this might cause the glass ampoule to burst. Let the SCBI cool down until it reaches room temperature. Check the Process Indicator on SCBI label. A color change to brown indicates that the SCBI has been exposed to Steam. IMPORTANT: This color change does not evidence the process effectiveness to achieve sterility. If the Process Indicator color has not changed, check the sterilization process. Press the lid to seal the tube. Crush the ampoule contained in the SCBI with an individual ampoule crusher or with the ampoule crusher placed within the incubator´s incubation area. Then shake the tube down vigorously, with movements similar to those performed to lower the temperature in a mercury thermometer, until the medium reaches the base of the tube and soaks the spore carrier entirely. Finally, place the SCBI in the incubator. Incubate the processed indicator and the positive control indicator in the appropriate Terragene® Bionova® Auto-Reader Incubators for a maximum of 1 hour at (60 ± 2) °C for super rapid readout. Specifications: Process: Steam Microorganism: Geobacillus stearothermophilus (ATCC 7953) Population: 10^6 Spores/carrier Read-Out Time: 1 h Regulations: IRAM 37102-1, IRAM 37102-3, ISO 11138-1, ISO 11138-3
SKU: BT222
$170.99 $136.99
Terragene Wash/Soil Test For Washers And Ultrasonics, 200 Strips/Bg
CDWA4 / Cleaning Indicator for cleaning performance tests. Challenge level: very high. Detects all the factors that affect the result of a washing process. Initial Color: Fuchsia. Result: removal of the fuchsia organic substance. Designed for routine control of cleaning processes and for monitoring automatic washing machines effectiveness as well as monitoring ultrasonic washing machines which operate at frequencies equal to or greater than 35 kHz, and temperatures between 30 ºC and 70 ºC. Characteristics: Challenge Level: Very high. Allows detection of all factors affecting the outcome of cleaning process. Initial Color: Fuchsia. Size: 70 mm x 30 mm (approximate). Synthetic temperature-stable support. Result: Elimination of fuchsia organic substance. To interpret results visually, use the results reference guide on product´s instructions for use. Optionally, the readout of the cleaning indicator can be done using Trazanto Automatic Quality Control and Traceability System (see instructions for use in device´s manual). Instructions For Use: Choose the Chemdye® Splat CDWA indicator according to the desired difficulty. Place the indicator on the Chemdye® Splat CDWAH or Chemdye® Splat CDWAH-U holder. Place the system on the tray along with the material. Once the cleaning cycle is over, remove the indicator. Analyze Chemdye® Splat CDWA indicators using the reference table and record results. If unfavorable results are obtained, perform the appropriate corrective actions and repeat the washing process. Specifications: Process: Cleaning and thermodisinfection Initial Color: Fuchsia Regulations: ISO 13485, ISO/TS 15883-5
SKU: CDWA4
$95.99 $81.99
Terragene Holder For CDWU-Z Ultrasonic Cleaning Indicator Vials. 10/Bg
Instructions For Use: Before The Test: Place the holder around the neck of the capsule. Press the holder down so that the groove of the holder fits securely around the neck of the vial. Insert the L shaped end on either side of the holder into the holes of the Ultrasonic device’s basket to hold the vial in position. The holder can be attached to a wire basket or perforated basket. Vials should be placed in the correct location within a tray / basket according to Ultrasonic Cleaning Indicator´s IFU based on the size of the tank. After the test is complete After the ultrasonic cycle remove the vial holding it with three fingers of one hand and the index finger and thumb of the other hand on the holder and lid of capsule. Place the index finger on the end of the holder, then place the thumb on the lid of the capsule for support, push the holder back off the neck of the capsule and remove the holder with both fingers.
SKU: CDWU-H
$36.99 $26.99
Terragene Holder For CDWA4 For Washers, 1/Bx
Holder for cleaning and thermodisinfection Indicators. Stainless Steel re-usable holder of great resistance and durability. Base: 32 mm wide, 72 mm long, pin at the back side. ISO/TS 15883-5. Designed to hold Chemdye® CDWA and Integron® IT27W indicators in order to perform routine control of cleaning and thermal disinfection processes in automatic machines. Characteristics: Chrome plating SUS304 grade stainless steel re-usable holder of great resistance and durability. Base: 32 mm wide, 72.5 mm long, pin at the back side. Basket: 32 mm wide, 37 mm long, 0.5 mm thick. The holder is designed to mimic the cleaning challenges posed by a large process load during the washing cycle and can be fixed on the tray, which allows reproducible location of the cleaning indicator in the washer-disinfector. When CDWA4 is placed within the holder, half of the test soil is obscured, thus simulating the joint of a surgical instrument, with water stream hitting it indirectly. The other half of the test soil is covered by a mesh, thus posing a difficulty for water stream to reach it, mimicking shadowed or occluded surfaces. The new design of CDWAH optimizes the control of the washer disinfectors ability to force water and detergent into and onto the test soil. Specifications: Process: Cleaning and thermodisinfection Regulations: ISO 15883
SKU: CDWA-H
$35.99 $26.99
Terragene Terragene Holder For CDWA4 For Ultrasonics, 1/Bx
CDWAH-U / Stainless steel re-usable holder of great resistance and durability. The holder is designed to be fixed on the tray, which allows reproducible location of the cleaning indicator in ultrasonic washing machines. Base: 32,7 mm wide, 72,5 mm long. Designed to hold Chemdye® CDWA cleaning indicators and perform routine control of cleaning processes in ultrasonic washers. Characteristics: Chrome plating SUS304 grade stainless steel re-usable holder of great resistance and durability. Base: 32 mm wide, 72.5 mm long, pin at the back side. The holder is designed to be fixed on the tray, which allows reproducible location of the cleaning indicator in ultrasonic washing machines, without representing a challenge to the washing process. Specifications: Process: Cleaning and thermodisinfection Regulations: ISO/TS 15883-5
SKU: CDWAH-U
$35.99 $29.99
Terragene Chemical Integrator, Steam, Single Point Type 5, 250/Bg
IT26-1YS / Unique point chemical integrator for Steam sterilization processes between 121° C and 134° C. Control of Steam sterilization processes between 121 ºC and 135 ºC. Characteristics: Type 5 Integrator Indicator (according to ISO 11140-1). One-side-laminated strips printed with indicator ink. Size: 70 mm x 23 mm. Initial Color: Yellow. Final Color: Black. 100 % Toxic Heavy Metal free. Instructions For Use: Place a chemical integrator Integron® IT26-1YS within each package, bag or tray that will be sterilized by Steam. In rigid containers place an IT26-1YS in every corner, or at least two diagonally opposite corners, to ensure that steam has reached the most inaccessible areas. Perform the sterilization cycle. After the sterilization process has finished, remove the indicators from the sterilizer and analyze the results. For all the chemical indicators exposed to Steam, the ink must turn to the black reference color when the integration conditions are reached. Specifications: Process: Steam Initial Color: Yellow Final Color: Black Indicator Type: Type 5 chemical indicator Regulations: ISO 11140-1 More Info About This Product: Color Chart
SKU: IT26-1YS
$25.99 $22.99
Terragene Chemical Integrator, ETO, Level 2 Type 5, 250/Bg
2 level chemical integrator for Ethylene Oxide sterilization processes. One-side laminated strips. Metals free. Integron® IT12 Chemical Integrators (Type 5 according to ISO 11140-1:2014 standard) are single-use two level chemical indicators that consist of paper strips laminated on the back side and printed with indicator ink. They have been designed for monitoring Ethylene Oxide (EO) sterilization processes. The integration level contains a purple/brown ink which was developed to turn to green when a theoretical spore population reaches its kill time, thus indicating that the SAFE condition has been met. Level 1 – Red: Exposure level. Indicator ink turns yellow to indicate exposition to the process, but does not ensure that the variables required to achieve the integration condition have been achieved (UNSAFE condition). Level 2 – Purple / brown: Integration level. Indicator ink turns green to indicate that the integration condition indicated in the quality certificate has been achieved. This condition consists of the kill time of a theoretical 106 Bacillus atrophaeus spore population, calculated in a BIER (Biological Indicator Evaluator Resistometer), and is called SAFE condition. Indicators 100% free of toxic heavy metals. Instructions For Use: Place a Integron® IT12 Chemical Integrator along with the material to be sterilized in a suitable package according to the recommended sterilization techniques. Place the indicators in those areas of most difficult access to the sterilizing agent. Perform the sterilization cycle. After the sterilization process has finished and evacuation/ventilation process is over, you may: A. Remove the integrator indicator taking the necessary precaution to avoid contact with the remaining sterilizing agent. B. Ventilate the load together with the integrator indicator and then perform the reading. Analyze the results. If the SAFE integration condition has been reached, the sterilization process has been effective. Specifications: Process: Ethylene Oxide Initial Color: Level 1 Red, Level 2 purple-brown Final Color: Level 1 Yellow, level 2 Green Indicator Type: Type 5 chemical indicator Regulations: ISO 11140-1 More Info About This Product: Color Chart
SKU: IT12
$18.99 $15.99