Description
IT26-C Extender/ Moving front Chemical Integrator to monitor Steam sterilization processes between 118°C and 138°C.
Control of Steam sterilization processes between 118 °C and 138 °C.
Characteristics:
Type 5 Integrating Indicator (according to ISO 11140-1).
Size: 52 mm x 21 mm.
Chemical Integrator consists of a paper wick and a steam and temperature sensitive chemical pellet contained in a paper/film/foil laminate. The chemical pellet melts and migrates as a dark bar along the paper wick. The migration is visible through a zone marked ACCEPT or REJECT, thus indicating whether sterilization conditions were met. The extent of migration depends on steam quality, time, and temperature.
The ACCEPT result is reached when a theoretical spore population reaches its kill time, indicating integration condition has been reached. This condition is calibrated with the kill time of 106 Geobacillus stearothermophilus spore population, calculated in BIER (Biological Indicator Evaluator Resistometer). Conditions: saturated steam at 121 °C, 128 °C, 135 °C.
Optionally, the readout of the chemical indicator can be done using Trazanto Automatic Quality Control and Traceability System (see instructions for use in device´s manual).
Instructions For Use:
- Carefully open the package and remove only the number of indicators needed.
- Reseal the package tightly.
- Place a Integron® IT26-C indicator in each pack, peel pouch, container system or tray to be steam sterilized in the most inaccessible area to sterilizing agent.
- Perform de sterilization cycle.
- 4After the sterilization process has finished, the dark bar should have reached the ACCEPT zone. If the dark bar has not reached the ACCEPT zone, a REJECT result is indicated and the items in the pack, peel pouch, container system, or tray were not exposed to proper steam sterilization conditions. These items should be reprocessed according to established procedures and a new IT26-C has to be used.
NOTE: In some extended or wet steam cycles, the dark bar can display discoloration in some zones of the reading window, imposing a difficulty for result´s interpretation (see Result Reference Guide for reference).
Despite this, regarding cycle integration parameters, this process can be considered as accepted. In case the IT26-C indicator shows a damp appearance after the sterilization process, Terragene® recommend planning an equipment´s maintenance.
- Brand
- Terragene
- SKU
- IT26-C-EXT
Terragene Chemical Integrator W/Extender, Steam, Moving Front Type 5, 250/Bg
Order as a Verified Dental Professional
To comply with U.S. regulations, regulated dental products are available to licensed professionals only.
- Free account
- Takes about 3 minutes
- One-time verification
- Faster reordering on future purchases
Already registered?
Log In
Assured Quality: 100% Satisfaction Guaranteed | Domestic U.S. Shipping Only
Best sellers
Handpicked essentials that dentists, hygienists, and surgeons rely on every single day.
EMS Mail-In Sterilizer Monitoring Service, 52 Tests/Box
FASTCheck15 In-Office 15 Minute Waterline Test Strip, 1 Strip/Pouch, 6 Pouches/Box
ConFirm Mail-In Premium - 12 Packets (3 Strip Test). Postage Paid. 12 Test
Bionova Fluorescence 20-Minute Steam SCBI Test Pack, 50/Pk
Bionova Fluorescence 4-Hour Rapid Ethylene Oxide SCBI, 50/Pk
Passport Plus Sterilizer Monitoring, Read-out Mail-in Biological Indicator
ConFirm Mail-In Value Test - 12 Packets (2 Strip Test). Postage Not Paid. 12
Bionova In-Office Biological Indicator Monitoring Starter Kit, 1/Pk
Frequently bought together
Bionova Fluorescence 20-Minute Steam SCBI Test Pack, 50/Pk
Bionova Fluorescence 4-Hour Rapid Ethylene Oxide SCBI, 50/Pk
Bionova In-Office Biological Indicator Monitoring Starter Kit, 1/Pk
Thermal Paper Roll For IC10/20FR And IC10/20FRLCD, 6rl/Bg
Strip Integrator Steam, 500/Bg
Bionova Biological Indicator, Rapid Fluorescence Readout, 50/Pk
Multivariable Process Indicator Strip, Type 4 For Plasma Or Vaporized Hydrogen Peroxide
Strip Integrator EO, 500/Bg
Customer reviews
Medical and Dental Supplies - Featured Collections
Frequently asked questions
When will my order ship?
Do I need a professional license to purchase this product?
Do I need an account to order from SurgiMac?
What if I need help before ordering?
What does “In Network” mean?
Will all items in my order arrive together?