Dynarex Dynarex Sterile Alcohol Prep Pads: Pre-moistened with 70% Isopropyl Alcohol
If you are a medical professional seeking a reliable and effective solution for skin preparation prior to injections or venipunctures, look no further than Dynarex Sterile Alcohol Prep Pads. Our premium single-use pads are pre-moistened with 70% isopropyl alcohol, ensuring rapid-acting antibacterial action to kill germs and bacteria on the skin. With a soft and absorbent non-woven pad, Dynarex Sterile Alcohol Prep Pads are designed to provide maximum absorbency for scrubbing and cleansing. Each pad is sealed in a sterile pouch to prevent dryness and maintain its hygienic properties, giving you peace of mind that the pad is ready for use whenever you need it. At Dynarex, we prioritize safety and reliability. Our Sterile Alcohol Prep Pads are gamma sterilized, guaranteeing that they meet the highest industry standards for sterility. Furthermore, these pads are made without natural rubber latex, ensuring compatibility for users with latex sensitivities. Key Features and Benefits: Pre-moistened with 70% isopropyl alcohol for effective disinfection Soft and absorbent non-woven pad for maximum scrubbing and cleansing By utilizing Dynarex Sterile Alcohol Prep Pads, you can maintain a clean and sterile environment, minimizing the risk of infection for both you and your patients. These pads are essential for any medical professional looking for a dependable and hygienic solution for skin preparation. Don't compromise on quality when it comes to the safety of your patients. Order your box of Dynarex Sterile Alcohol Prep Pads today and experience the difference they can make in your practice.
O&M Halyard Inc Urological Drape Gyn / Urological Drape 112 W X 63 W X 131 L Inch Sterile
Pouch with mesh screen and port Attached Leggings Control™ Fabric Reinforcement With tube holders Armboard Covers Manufacturer O&M Halyard Inc Country of Origin China Application Urological Drape Color Blue Dimensions 112 W X 63 W X 131 L Inch Drape Name Gyn / Urological Drape Extremity Cover Arm Covers / Leggings, Attached Fluid Collection Type Fluid Collection Pouch Instrument Holders Without Instrument Holder Material Polypropylene Pouch Specifications Mesh Screen, Port Reinforcement Type Control™ Fabric Reinforcement Securing Method Without Adhesive Sterility Sterile Surgical Area Fenestrated Surgical Area Specifications Rectangle 3 X 6 Inch Perineal Fenestration Tube and Cord Holders Cord and Tube Holders
SKU: 89204
$290.00 $252.00
3M Urology Drape, 23" x 95", Adhesive Strip, 2" Circle Aperture, Finger Cot with Adhesive
Impervious polyethylene film creates a sterile surface around the surgical site. (Can be used to create a sterile field.) Matte finish helps reduce glare from the drape surface during the procedure. Manufacturer # 1071 Brand 3M™ Steri-Drape™ Manufacturer 3M Country of Origin United States Application Urological Drape Color Clear Dimensions 23 W X 35 L Inch Drape Name Urological Drape Extremity Cover Without Covers Fluid Collection Type Without Pouch Instrument Holders Without Instrument Holder Material Plastic Reinforcement Type Without Reinforcement Securing Method Adhesive Strip / Adhesive Cot Sterility Sterile Surgical Area Fenestrated / Finger Cot Surgical Area Specifications Circular 2 Inch Aperture Tube and Cord Holders Without Cord and Tube Holders UNSPSC Code 42131701 Latex Free Indicator Not Made with Natural Rubber Latex
SKU: 1071-40
$525.29 $455.25
Terragene Steam Chemical Integrator, 250/Bg
IT26-C / Moving front Chemical Integrator to monitor Steam sterilization processes between 118°C and 138°C. Control of Steam sterilization processes between 118 °C and 138 °C. Characteristics: Type 5 Integrating Indicator (according to ISO 11140-1). Size: 52 mm x 21 mm. Chemical Integrator consists of a paper wick and a steam and temperature sensitive chemical pellet contained in a paper/film/foil laminate. The chemical pellet melts and migrates as a dark bar along the paper wick. The migration is visible through a zone marked ACCEPT or REJECT, thus indicating whether sterilization conditions were met. The extent of migration depends on steam quality, time, and temperature. The ACCEPT result is reached when a theoretical spore population reaches its kill time, indicating integration condition has been reached. This condition is calibrated with the kill time of 106 Geobacillus stearothermophilus spore population, calculated in BIER (Biological Indicator Evaluator Resistometer). Conditions: saturated steam at 121 °C, 128 °C, 135 °C. Optionally, the readout of the chemical indicator can be done using Trazanto Automatic Quality Control and Traceability System (see instructions for use in device´s manual). Instructions For Use: Carefully open the package and remove only the number of indicators needed. Reseal the package tightly. Place a Integron® IT26-C indicator in each pack, peel pouch, container system or tray to be steam sterilized in the most inaccessible area to sterilizing agent. Perform de sterilization cycle. After the sterilization process has finished, the dark bar should have reached the ACCEPT zone. If the dark bar has not reached the ACCEPT zone, a REJECT result is indicated and the items in the pack, peel pouch, container system, or tray were not exposed to proper steam sterilization conditions. These items should be reprocessed according to established procedures and a new IT26-C has to be used. Despite this, regarding cycle integration parameters, this process can be considered as accepted. In case the IT26-C indicator shows a damp appearance after the sterilization process, Terragene® recommend planning an equipment´s maintenance. Specifications: Process: Steam Indicator Type: Type 5 chemical indicator Regulations: ISO 11140-1 More Info About This Product: User Manual
SKU: IT26-C
$45.99 $37.99
Terragene Chemical Integrator W/Extender, Steam, Moving Front Type 5, 250/Bg
IT26-C Extender/ Moving front Chemical Integrator to monitor Steam sterilization processes between 118°C and 138°C. Control of Steam sterilization processes between 118 °C and 138 °C. Characteristics: Type 5 Integrating Indicator (according to ISO 11140-1). Size: 52 mm x 21 mm. Chemical Integrator consists of a paper wick and a steam and temperature sensitive chemical pellet contained in a paper/film/foil laminate. The chemical pellet melts and migrates as a dark bar along the paper wick. The migration is visible through a zone marked ACCEPT or REJECT, thus indicating whether sterilization conditions were met. The extent of migration depends on steam quality, time, and temperature. The ACCEPT result is reached when a theoretical spore population reaches its kill time, indicating integration condition has been reached. This condition is calibrated with the kill time of 106 Geobacillus stearothermophilus spore population, calculated in BIER (Biological Indicator Evaluator Resistometer). Conditions: saturated steam at 121 °C, 128 °C, 135 °C. Optionally, the readout of the chemical indicator can be done using Trazanto Automatic Quality Control and Traceability System (see instructions for use in device´s manual). Instructions For Use: Carefully open the package and remove only the number of indicators needed. Reseal the package tightly. Place a Integron® IT26-C indicator in each pack, peel pouch, container system or tray to be steam sterilized in the most inaccessible area to sterilizing agent. Perform de sterilization cycle. 4After the sterilization process has finished, the dark bar should have reached the ACCEPT zone. If the dark bar has not reached the ACCEPT zone, a REJECT result is indicated and the items in the pack, peel pouch, container system, or tray were not exposed to proper steam sterilization conditions. These items should be reprocessed according to established procedures and a new IT26-C has to be used. NOTE: In some extended or wet steam cycles, the dark bar can display discoloration in some zones of the reading window, imposing a difficulty for result´s interpretation (see Result Reference Guide for reference). Despite this, regarding cycle integration parameters, this process can be considered as accepted. In case the IT26-C indicator shows a damp appearance after the sterilization process, Terragene® recommend planning an equipment´s maintenance.
SKU: IT26-C EXT
$40.99 $31.99
O&M Halyard Inc Urological Drape Lithotomy Drape 87 W X 30 W X 100 L Inch Sterile
Control™ Fabric Reinforcement Tube Holders Attached Leggings Manufacturer O&M Halyard Inc Country of Origin Mexico Application Urological Drape Color Blue Dimensions 87 W X 30 W X 100 L Inch Drape Name Lithotomy Drape Extremity Cover Arm Covers / Leggings, Attached Fluid Collection Type Without Pouch Instrument Holders Without Instrument Holder Material Polypropylene Reinforcement Type Control™ Fabric Reinforcement Securing Method Adhesive Fenestration Sterility Sterile Surgical Area Fenestrated Surgical Area Specifications Rectangle 3 X 6 Inch Perineal Fenestration Tube and Cord Holders Cord and Tube Holders