Search results for "Sterilization Pouches*"
Terragene Steam Chemical Integrator, 250/Bg
IT26-C / Moving front Chemical Integrator to monitor Steam sterilization processes between 118°C and 138°C. Control of Steam sterilization processes between 118 °C and 138 °C. Characteristics: Type 5 Integrating Indicator (according to ISO 11140-1). Size: 52 mm x 21 mm. Chemical Integrator consists of a paper wick and a steam and temperature sensitive chemical pellet contained in a paper/film/foil laminate. The chemical pellet melts and migrates as a dark bar along the paper wick. The migration is visible through a zone marked ACCEPT or REJECT, thus indicating whether sterilization conditions were met. The extent of migration depends on steam quality, time, and temperature. The ACCEPT result is reached when a theoretical spore population reaches its kill time, indicating integration condition has been reached. This condition is calibrated with the kill time of 106 Geobacillus stearothermophilus spore population, calculated in BIER (Biological Indicator Evaluator Resistometer). Conditions: saturated steam at 121 °C, 128 °C, 135 °C. Optionally, the readout of the chemical indicator can be done using Trazanto Automatic Quality Control and Traceability System (see instructions for use in device´s manual). Instructions For Use: Carefully open the package and remove only the number of indicators needed. Reseal the package tightly. Place a Integron® IT26-C indicator in each pack, peel pouch, container system or tray to be steam sterilized in the most inaccessible area to sterilizing agent. Perform de sterilization cycle. After the sterilization process has finished, the dark bar should have reached the ACCEPT zone. If the dark bar has not reached the ACCEPT zone, a REJECT result is indicated and the items in the pack, peel pouch, container system, or tray were not exposed to proper steam sterilization conditions. These items should be reprocessed according to established procedures and a new IT26-C has to be used. Despite this, regarding cycle integration parameters, this process can be considered as accepted. In case the IT26-C indicator shows a damp appearance after the sterilization process, Terragene® recommend planning an equipment´s maintenance. Specifications: Process: Steam Indicator Type: Type 5 chemical indicator Regulations: ISO 11140-1 More Info About This Product: User Manual
SKU: IT26-C
$45.99 $37.99
Terragene Chemical Integrator W/Extender, Steam, Moving Front Type 5, 250/Bg
IT26-C Extender/ Moving front Chemical Integrator to monitor Steam sterilization processes between 118°C and 138°C. Control of Steam sterilization processes between 118 °C and 138 °C. Characteristics: Type 5 Integrating Indicator (according to ISO 11140-1). Size: 52 mm x 21 mm. Chemical Integrator consists of a paper wick and a steam and temperature sensitive chemical pellet contained in a paper/film/foil laminate. The chemical pellet melts and migrates as a dark bar along the paper wick. The migration is visible through a zone marked ACCEPT or REJECT, thus indicating whether sterilization conditions were met. The extent of migration depends on steam quality, time, and temperature. The ACCEPT result is reached when a theoretical spore population reaches its kill time, indicating integration condition has been reached. This condition is calibrated with the kill time of 106 Geobacillus stearothermophilus spore population, calculated in BIER (Biological Indicator Evaluator Resistometer). Conditions: saturated steam at 121 °C, 128 °C, 135 °C. Optionally, the readout of the chemical indicator can be done using Trazanto Automatic Quality Control and Traceability System (see instructions for use in device´s manual). Instructions For Use: Carefully open the package and remove only the number of indicators needed. Reseal the package tightly. Place a Integron® IT26-C indicator in each pack, peel pouch, container system or tray to be steam sterilized in the most inaccessible area to sterilizing agent. Perform de sterilization cycle. 4After the sterilization process has finished, the dark bar should have reached the ACCEPT zone. If the dark bar has not reached the ACCEPT zone, a REJECT result is indicated and the items in the pack, peel pouch, container system, or tray were not exposed to proper steam sterilization conditions. These items should be reprocessed according to established procedures and a new IT26-C has to be used. NOTE: In some extended or wet steam cycles, the dark bar can display discoloration in some zones of the reading window, imposing a difficulty for result´s interpretation (see Result Reference Guide for reference). Despite this, regarding cycle integration parameters, this process can be considered as accepted. In case the IT26-C indicator shows a damp appearance after the sterilization process, Terragene® recommend planning an equipment´s maintenance.
SKU: IT26-C EXT
$40.99 $31.99
3M Dressing, 19.1" Hexagon Sheet
This matrix is a protease modulating matrix composed of collagen and oxidized regenerated cellulose (ORC) The dressings were developed to maintain a moist microenvironment that is conducive to granulation tissue formation, epithelialization, and rapid wound healing The matrix is a freeze dried composite that consists of 55% collagen and 45% oxidized regenerated cellulose (ORC) Indicated for the management of all wounds healing by secondary intent which are clear of necrotic tissue, including: venous leg ulcers, diabetic foot ulcers, pressure ulcers, traumatic and surgical wounds Packaged in a transparent waterproof peel pouch, sealed with a laminated cover More Information MSDS Manufacturer # PG019 Brand 3M™ Promogran™ Matrix Manufacturer 3M Systagenix/KCI Country of Origin United Kingdom Application Collagen Dressing Color White Dimensions 19-1/10 X 19-1/10 Inch HCPCS A6022 Length 13 to 24 Inch Length Material Collagen / (ORC) Oxidized Regenerated Cellulose Shape Hexagon Sterility Sterile UNSPSC Code 42311500 Width 16 to 20 Inch Width
Dynarex Medi-Cut Surgical Blade
The Medi-Cut Surgical Blade by Dynarex is a precision instrument designed for exceptional performance in medical procedures. Crafted with a high-quality stainless-steel blade, this surgical tool delivers precise and accurate cutting with every use. The blade features a finely honed cutting edge, ensuring clean and precise incisions every time. With its sharpness and durability, the Medi-Cut Surgical Blade is a reliable choice for medical professionals. Whether it's a routine procedure or a complex surgery, this blade provides the accuracy and control needed for optimal outcomes. Its ergonomic handle offers a comfortable grip, allowing for precise and controlled movements. The individually packaged Medi-Cut Surgical Blades are conveniently sterilized and sealed in peel-open pouches. This ensures the highest level of hygiene and reduces the risk of contamination. Each blade is ready for immediate use, saving valuable time in medical settings. The Medi-Cut Surgical Blade offers the following key features and benefits: Precision cutting: The stainless-steel blade with a finely honed cutting edge ensures precise and accurate incisions. Hygienic packaging: Each blade is individually sterilized and packaged in a peel-open pouch for optimal hygiene. Specifications: Material: Stainless steel Blade type: Surgical blade Invest in the reliable and high-performing Medi-Cut Surgical Blade for superior precision in medical procedures. With its exceptional cutting abilities and hygienic packaging, this blade is a must-have for any medical professional seeking quality and reliability.
3M Dressing, 4.34" Hexagon Sheet
This matrix is a protease modulating matrix composed of collagen and oxidized regenerated cellulose (ORC) The dressings were developed to maintain a moist microenvironment that is conducive to granulation tissue formation, epithelialization, and rapid wound healing The matrix is a freeze dried composite that consists of 55% collagen and 45% oxidized regenerated cellulose (ORC) Indicated for the management of all wounds healing by secondary intent which are clear of necrotic tissue, including: venous leg ulcers, diabetic foot ulcers, pressure ulcers, traumatic and surgical wounds Packaged in a transparent waterproof peel pouch, sealed with a laminated cover More Information MSDS Manufacturer # PG004 Brand 3M™ Promogran™ Matrix Manufacturer 3M Systagenix/KCI Country of Origin United Kingdom Application Collagen Dressing Color White Dimensions 4-1/3 X 4-1/3 Inch HCPCS A6021 Length Up to 4 Inch Length Material Collagen / (ORC) Oxidized Regenerated Cellulose Shape Hexagon Sterility Sterile UNSPSC Code 42311500 Width 4 Inch Width