Search results for "Sterilization Pouches*"
McKesson Safety Scalpel Stainless Steel / Plastic Sensory Grip Handle Sterile Disposable
McKesson Prevent®B Safety Scalpels No. 10-Packaged: 1 Per Pouch, 10 Pouches Per Box, 20 Boxes Per Case No. 11-Packaged: 1 Per Pouch, 10 Pouches Per Box, 20 Boxes Per Case No. 15-Packaged: 1 Per Pouch, 10 Pouches Per Box, 20 Boxes Per Case Sterile Stainless steel surgical blade. Eliminates the risk associated with installing or removing blades. Laser-controlled edge. Ergonomically designed for better feel and precision. Graduated scale. Single hand operation. Three positions (USE, PASS and DISPOSE), with steadfast disposal lock. Locks into USE position. Disposal lock status indicator. Retractable blade design. Single Use Not made with natural rubber latex.
McKesson Safety Scalpel McKesson Prevent Stainless Steel / Plastic Sensory Grip Handle Sterile Disposable
McKesson Prevent® MX Safety Scalpels No. 15 Sterile Stainless steel surgical blade. Eliminates the risk associated with installing or removing blades. Laser-controlled edge. Ergonomically designed for better feel and precision. Graduated scale. Single hand operation. Three positions (USE, PASS and DISPOSE), with steadfast disposal lock. Locks into USE position. Disposal lock status indicator. Retractable blade design. Single Use Not made with natural rubber latex. Packaged: 1 Per Pouch, 10 Pouches Per Box, 50 Boxes Per Case Manufacturer # 1645 Brand McKesson Prevent® MX Manufacturer McKesson Brand Country of Origin India Application Safety Scalpel Grade Surgical Grade Handle Type Sensory Grip Handle Material Stainless Steel / Plastic Sterility Sterile UNSPSC Code 42291613 Usage Disposable Latex Free Indicator Not Made with Natural Rubber Latex
Dynarex Medi-Cut Safety Scalpels / Plastic Sensory Grip Handle Sterile Disposable
Introducing the Medi-Cut Safety Scalpels, the perfect solution for ensuring precise and safe incisions during medical procedures. Designed with the utmost attention to detail, these scalpels combine functionality and safety to deliver exceptional performance in hospitals and clinics. Featuring a high-quality stainless steel blade, the Medi-Cut Safety Scalpels offer unparalleled precision and durability. With a single fluid motion, the blade effortlessly retracts and securely locks inside the handle, eliminating the risk of accidental cuts and ensuring safe disposal. This innovative design not only enhances the safety of medical professionals but also minimizes the potential for cross-contamination. The Medi-Cut Safety Scalpels come individually packaged in convenient pouches, ensuring sterility and easy accessibility when needed. Each scalpel is meticulously crafted to meet the highest standards of quality, providing medical practitioners with confidence in every procedure. Key Features: Precise and Safe Incisions: The stainless steel blade ensures accurate and clean cuts, while the retractable design eliminates the risk of injury during disposal. Enhanced Safety: The blade locks securely inside the handle, minimizing the potential for accidental cuts and reducing the risk of cross-contamination. In addition to their exceptional features, the Medi-Cut Safety Scalpels also meet industry specifications: Blade Material: Stainless steel Blade Retraction: Single motion, permanent lock Package Contents: Individually packaged Elevate your medical procedures to the next level with the Medi-Cut Safety Scalpels. Designed to deliver unparalleled safety and precision, these scalpels are an essential tool for any hospital or clinic. Invest in quality and ensure the well-being of both medical professionals and patients.
Terragene Chemical Integrator W/Extender, Steam, Moving Front Type 5, 250/Bg
IT26-C Extender/ Moving front Chemical Integrator to monitor Steam sterilization processes between 118°C and 138°C. Control of Steam sterilization processes between 118 °C and 138 °C. Characteristics: Type 5 Integrating Indicator (according to ISO 11140-1). Size: 52 mm x 21 mm. Chemical Integrator consists of a paper wick and a steam and temperature sensitive chemical pellet contained in a paper/film/foil laminate. The chemical pellet melts and migrates as a dark bar along the paper wick. The migration is visible through a zone marked ACCEPT or REJECT, thus indicating whether sterilization conditions were met. The extent of migration depends on steam quality, time, and temperature. The ACCEPT result is reached when a theoretical spore population reaches its kill time, indicating integration condition has been reached. This condition is calibrated with the kill time of 106 Geobacillus stearothermophilus spore population, calculated in BIER (Biological Indicator Evaluator Resistometer). Conditions: saturated steam at 121 °C, 128 °C, 135 °C. Optionally, the readout of the chemical indicator can be done using Trazanto Automatic Quality Control and Traceability System (see instructions for use in device´s manual). Instructions For Use: Carefully open the package and remove only the number of indicators needed. Reseal the package tightly. Place a Integron® IT26-C indicator in each pack, peel pouch, container system or tray to be steam sterilized in the most inaccessible area to sterilizing agent. Perform de sterilization cycle. 4After the sterilization process has finished, the dark bar should have reached the ACCEPT zone. If the dark bar has not reached the ACCEPT zone, a REJECT result is indicated and the items in the pack, peel pouch, container system, or tray were not exposed to proper steam sterilization conditions. These items should be reprocessed according to established procedures and a new IT26-C has to be used. NOTE: In some extended or wet steam cycles, the dark bar can display discoloration in some zones of the reading window, imposing a difficulty for result´s interpretation (see Result Reference Guide for reference). Despite this, regarding cycle integration parameters, this process can be considered as accepted. In case the IT26-C indicator shows a damp appearance after the sterilization process, Terragene® recommend planning an equipment´s maintenance.
SKU: IT26-C EXT
$40.99 $31.99
Terragene Steam Chemical Integrator, 250/Bg
IT26-C / Moving front Chemical Integrator to monitor Steam sterilization processes between 118°C and 138°C. Control of Steam sterilization processes between 118 °C and 138 °C. Characteristics: Type 5 Integrating Indicator (according to ISO 11140-1). Size: 52 mm x 21 mm. Chemical Integrator consists of a paper wick and a steam and temperature sensitive chemical pellet contained in a paper/film/foil laminate. The chemical pellet melts and migrates as a dark bar along the paper wick. The migration is visible through a zone marked ACCEPT or REJECT, thus indicating whether sterilization conditions were met. The extent of migration depends on steam quality, time, and temperature. The ACCEPT result is reached when a theoretical spore population reaches its kill time, indicating integration condition has been reached. This condition is calibrated with the kill time of 106 Geobacillus stearothermophilus spore population, calculated in BIER (Biological Indicator Evaluator Resistometer). Conditions: saturated steam at 121 °C, 128 °C, 135 °C. Optionally, the readout of the chemical indicator can be done using Trazanto Automatic Quality Control and Traceability System (see instructions for use in device´s manual). Instructions For Use: Carefully open the package and remove only the number of indicators needed. Reseal the package tightly. Place a Integron® IT26-C indicator in each pack, peel pouch, container system or tray to be steam sterilized in the most inaccessible area to sterilizing agent. Perform de sterilization cycle. After the sterilization process has finished, the dark bar should have reached the ACCEPT zone. If the dark bar has not reached the ACCEPT zone, a REJECT result is indicated and the items in the pack, peel pouch, container system, or tray were not exposed to proper steam sterilization conditions. These items should be reprocessed according to established procedures and a new IT26-C has to be used. Despite this, regarding cycle integration parameters, this process can be considered as accepted. In case the IT26-C indicator shows a damp appearance after the sterilization process, Terragene® recommend planning an equipment´s maintenance. Specifications: Process: Steam Indicator Type: Type 5 chemical indicator Regulations: ISO 11140-1 More Info About This Product: User Manual
SKU: IT26-C
$45.99 $37.99